(25)
13
Single Measurements
13.1 General
•
Any measuring duration is possible.
•
The respective measurement is started
and ended by pressing
START/
STOP
.
•
No limit values can be specified for single
measurements, and thus there’s no eval-
uation.
•
Checking is performed before
each
measurement in order to assure a trou-
ble-free sequence, and to prevent any
damage to the DUT.
13.2 Measurement Procedure and Storage
The measured value can be captured by
pressing the save key or several measured
values, i.e. a measurement series, can be
acquired by repeatedly pressing the key. The
save key indicates in each case whether one
or several measured values have been
acquired.
The measurements or measurement series
can be saved after measurement has been
completed.
Note
Measured values can only be added
to the clipboard during a measure-
ment.
If no measured values have been
copied to the clipboard before the
STOP
key (interrupt/pause, end) is
pressed, the last value is automati-
cally saved so that no “empty” mea-
surements or measurement series
are saved.
The procedure for saving data depends on
whether or not the DUT has already been
created as a test object in the test instru-
ment’s database. Only the latter is described
in this document. Refer to the operating
instructions for saving data under test
objects that have already been created.
1 Start the measurement by press-
ing the
START/
STOP
key
The icon shown at the right
appears and indicates how many mea-
surements have already been per-
formed.
2 End the measurement by press-
ing the
START/
STOP
key (unless a
specified measuring time has
been stipulated).
The save icon (floppy disk with a num-
ber) appears and indicates that one or
more valid measured values have been
captured, which can now be saved.
3 Press the
save icon
(floppy disk).
You’re informed that you haven’t
selected a test object in the data-
base.
4 Optional: If you want to view the
measured values, press the
AΩV
key. Details concerning the indi-
vidual measured value can be
accessed via the
magnifying glass
icon.
Use the green checkmark in order to
return to the memory menu.
5 Optional: Enter a comment via
the icon which depicts a sheet of
paper and a pencil.
6 Press the
ID
key.
You now have the option of
entering a test object ID number.
If you enter an ID here which is
not yet
included in the database, a
prompt appears asking you if you want
to enter a new test object.
Note
If you haven’t yet set up a customer,
you must do so now. Follow the
instructions which appear in the dia-
log.
7 The test object can then be created:
– Select either device or (medical) ME
device.
3