12

SPLIT SYSTEMS

AIR CONDITIONING AND HEAT PUMP HOMEOWNER’S

 

ROUTINE MAINTENANCE RECOMMENDATIONS

We strongly recommend a bi-annual maintenance checkup be performed

before the heating and cooling seasons begin by a 

qualified servicer

.

R

EPLACE

 

OR

 C

LEAN

 F

ILTER

IMPORTANT NOTE: 

Never operate unit without a filter installed

as dust and lint will build up on internal parts resulting in loss
of efficiency, equipment damage and possible fire.

An indoor air filter must be used with your comfort system. A
properly maintained filter will keep the indoor coil of your com-
fort system clean. A dirty coil could cause poor operation and/
or severe equipment damage.

Your air filter or filters could be located in your furnace, in a
blower unit, or in “filter grilles” in your ceiling or walls. The
installer of your air conditioner or heat pump can tell you where
your filter(s) are, and how to clean or replace them.

Check your filter(s) at least once a month. When they are
dirty, replace or clean as required. Disposable type filters should
be replaced. Reusable type filters may be cleaned.

You may want to ask your dealer about high efficiency filters.
High efficiency filters are available in both electronic and non-
electronic types. These filters can do a better job of catching
small airborne particles.

C

OMPRESSOR

The compressor motor is hermetically sealed and does not
require additional oiling.

M

OTORS

Indoor and outdoor fan motors are permanently lubricated and
do not require additional oiling.

C

LEAN

 O

UTSIDE

 C

OIL

 (Q

UALIFIED

 S

ERVICER

 O

NLY

)

Air must be able to flow through the outdoor unit of your com-
fort system. Do not construct a fence near the unit or build a
deck or patio over the unit without first discussing your plans
with your  dealer or other qualified servicer. Restricted airflow
could lead to poor operation and/or severe equipment damage.

Likewise, it is important to keep the outdoor coil clean. Dirt,
leaves, or debris could also restrict the airflow. If cleaning of
the outdoor coil becomes necessary, hire a qualified servicer.
Inexperienced people could easily puncture the tubing in the
coil. Even a small hole in the tubing could eventually cause a
large loss of refrigerant. Loss of refrigerant can cause poor
operation and/or severe equipment damage.

Do not use a condensing unit cover to “protect” the outdoor
unit during the winter, unless you first discuss it with your
dealer. Any cover used must include “breathable” fabric to avoid
moisture buildup.

Check the thermostat to confirm that it is properly set.

Wait 15 minutes. Some devices in the outdoor unit or in

programmable thermostats will prevent compressor op-
eration for awhile, and then reset automatically. Also, some
power companies will install devices which shut off air
conditioners for several minutes on hot days. If you wait
several minutes, the unit may begin operation on its own.

T

O

 

AVOID

 

THE

 

RISK

 

OF

 

EQUIPMENT

 

DAMAGE

 

OR

 

FIRE

INSTALL

THE

 

SAME

 

AMPERAGE

 

BREAKER

 

OR

 

FUSE

 

AS

 

YOU

 

ARE

REPLACING

.  I

F

 

THE

 

CIRCUIT

 

BREAKER

 

OR

 

FUSE

 

SHOULD

 

OPEN

AGAIN

 

WITHIN

 

THIRTY

 

DAYS

CONTACT

 

A

 

QUALIFIED

 

SERVICER

TO

 

CORRECT

 

THE

 

PROBLEM

.

I

F

 

YOU

 

REPEATEDLY

 

RESET

 

THE

 

BREAKER

 

OR

 

REPLACE

THE

 

FUSE

 

WITHOUT

 

HAVING

 

THE

 

PROBLEM

 

CORRECTED

,

YOU

 

RUN

 

THE

 

RISK

 

OF

 

SEVERE

 

EQUIPMENT

 

DAMAGE

.

B

EFORE

 C

ALLING

 Y

OUR

 S

ERVICER

Check the electrical panel  for tripped circuit breakers  or

failed fuses. Reset the circuit breakers or replace fuses
as necessary.

Check the disconnect switch near the indoor furnace or

blower to confirm that it is closed.

Check for obstructions on the outdoor unit . Confirm that

it has not been covered on the sides or the top. Remove
any obstruction that can be safely  removed. If  the unit is
covered with dirt or debris, call a qualified servicer to clean
it.

Check for blockage of the indoor air inlets and outlets.

Confirm that they are open and have not been blocked by
objects (rugs, curtains or furniture).

Check the filter. If it is dirty, clean or replace it.

Listen for any unusual noise(s), other than normal oper-

ating noise, that might be coming from the outdoor unit.
If you hear unusual noise(s) coming from the unit, call a
qualified servicer.

Содержание IO-402K

Страница 1: ...it upright laying the unit on its side or top may cause equipment damage Shipping damage and subse quent investigation is the responsibility of the carrier Verify the model number specifications elect...

Страница 2: ...not shift or settle To reduce the possibility of sound transmission the foundation slab should not be in contact with or be an integral part of the building foundation Ensure the foundation is suffici...

Страница 3: ...ooling Service Manual or TP 106 Long Line Set Application R 22 or contact your distributor for assistance Cond Unit Tons Suct Liq Suct Liq Suct Liq 1 1 2 5 8 1 4 3 4 3 8 3 4 3 8 2 5 8 1 4 3 4 3 8 3 4...

Страница 4: ...dents Any other condition increases the chance of a refrigerant leak 2 Sweep the refrigerant line with nitrogen or inert gas dur ing brazing to prevent the formation of copper oxide in side the refri...

Страница 5: ...ring this period If the pressure rises to 1000 microns or less and remains steady the system is considered leak free proceed to startup 5000 4500 4000 3500 3000 2500 2000 1500 1000 500 0 1 2 3 4 5 6 7...

Страница 6: ...a possible refrigerant leak open the service valves until the top of the stem is 1 8 from the retainer CAUTION When opening valves with retainers open each valve only until the top of the stem is 1 8...

Страница 7: ...OR OTHER PENALTIES Operating the compressor with the suction valve closed may cause serious compressor damage CAUTION Final Charge Adjustment The outdoor temperature must be 60 F or higher Set the ro...

Страница 8: ...25 n a 435 n a 445 n a 475 n a 500 n a 525 n a 550 n a 575 n a 600 n a 625 n a SATURATED LIQUID PRESSURE TEMPERATURE CHART SUCTION PRESSURE SATURATED SUCTION TEMPERATURE F PSIG R 22 50 26 52 28 54 29...

Страница 9: ...essure to stabilize 2 Temporarily install thermometer on liquid small line near liquid line service valve with adequate contact and insu late for best possible reading 3 Check subcooling and superheat...

Страница 10: ...it Test Control Circuit with Voltmeter Low Voltage Test Voltage Faulty Evaporator Fan Motor Repair or Replace Shorted or Grounded Fan Motor Test Motor Windings Improper Cooling Anticipator Check Resis...

Страница 11: ...11 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 12: ...airflow If cleaning of the outdoor coil becomes necessary hire a qualified servicer Inexperienced people could easily puncture the tubing in the coil Even a small hole in the tubing could eventually c...

Отзывы: