38 www.goodmanmfg.com 

SS-CPG36-72

w

irinG

 d

iaGram

 —

 CPG036/480453B (t

hree

-P

hase

, B

elt

 d

rive

)

Wiring

 is

 subject

 to

 change.

 Al

wa

ys

 

refer

 to

 the

 wiring

 diag

ram

 or

 the

 

unit

 for

 the

 most

 up-to-da

te

 wiring

.

   

w

arnin

G

High 

Voltage:

 Disconnect

 all

 power

 bef

or

ser

vicing

 or

 installing

 this

 unit.

 Multiple

 power

  

sour

ces

 ma

be

 pr

esent.

 F

ailur

to

 do

 so

 ma

cause

 pr

operty

 damage,

 per

sonal

 injur

y,

 or

 dea

th.

WH

WH

L1

BR

FS

RD

DI

BL

RD

YL

YL

GR

YL

PU

5

4

1

2

NOTE 2

PLF

6

3

YL

RS

GR

HEA

T

CO

OL

UN

US

ED

BL

BL

L2

BL

YL

MV

MV

PU

PU

W. R.

GAS VALVE

GV

BL

(ALT.) HONEYWELL

GAS VALVE

GV

GR

SEE
NOTE 3

FS

IGN

BK

VM

OR

RD

FC

RD

BR

RD

WH

YL

HPS

LPS

YL/PK

BL/PK

BL

R

C

Y2 Y1

YL

BL

RD

TO THERMOSTAT

G

GR

BL

PU

WH

W1

F

C

GND

T3

RD

L3

POWER SUPPLY

YL

BK

208-240/3/60

YL

IIC

T1

T2

BK

PU

YL

BK

RD

C

L1

L2

BL

BL

RD

RD

BK

T3 T2

T1

PU

COMP

CM

BR

BK

RD

RD

LS

GR

10

7

9

12

8

11

ECON

BL

PU

RD

RD

1

3

2

6

5

4

YL

PU

YL

PS

ALS

OR

RD

BK

OR

EM

WH

VMR

BL

24V

TR

BL

BL

1

240

2

3

C

BK

OR

RD

OR

BL

GR

T2

T3

T1

C

BC

BK

208

L3

L2

L1

S1

S2

PK

TB1

SMOKE/FIRE DETECTOR
REPLACES JUMPER
WIRE

BR

GR

RD

3

1

2

OR

OR

SEE NOTE 4

BK

BK

BK

208-240/3/60

0140L00979

REV B

INSTALLER/SERVICEMAN

TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:

THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO

FALSE FLAME SENSED

OPEN LIMIT SWITCH

WITHOUT INDUCER ON

PRESSURE SWITCH CLOSED

PRESSURE SWITCH

NORMAL OPERATION

INTERNAL CONTROL

3 BLINKS

6 BLINKS

4 BLINKS

5 BLINKS

OUTPUT DELAY

COMPRESSOR

OFF

ON

1 BLINK

2 BLINKS

STATUS LIGHT

OPEN AUX. LIMIT

IGNITION FAILURE

OPEN ROLLOUT

SWITCH

OPEN

SWITCH

NO POWER OR

EQUIP. STATUS

CHECK

ANTI-CYCLE TIMER

MAIN LIMIT OPEN

STICKING GAS VALVE

BAD SWITCH

3 MIN. COMP.

PRESSURE SWITCH

GAS PRESSURE

FLAME ROLLOUT

AUX. LIMIT OPEN

FLAME SENSOR

BAD SWITCH

GAS VALVE

REPLACE CONTROL

GAS FLOW

PRESSURE SWITCH

CHECK

CHECK FUSE ON CONTROL

CHECK INPUT POWER

-

CHECK

TRANSFORMER

TR

ALS

COMP

COMPONENT LEGEND

COMPRESSOR

EM

IIC
IGN

GND

FS

GV

C

F

FUSE

FC

EVAPORATOR MOTOR

FLAME SENSOR

EQUIPMENT GROUND

IGNITOR

GAS VALVE

CONTACTOR

FAN CAPACITOR

RS

TB1

PLF

PS

VM
VMR

ROLLOUT SWITCH
TERMINAL BLOCK (24V SIGNAL)

PRESSURE SWITCH

VENT MOTOR
VENT MOTOR RELAY

LIMIT SWITCH

LS

CONDENSER MOTOR

CM

INTEGRATED IGNITION CONTROL

FEMALE PLUG/CONNECTOR

AUXILIARY LIMIT SWITCH

IBR

INDOOR BLOWER RELAY

BC

BLOWER CONTACTOR

BC

L2

L3

C

L2

L3

CM

T3

C

FC

208-240/3/60

T2

T3

T2

T1

T1

COMP

L1

C

L1

SUPPLY VOLTAGE

1

3

3

VMR

BC

IIC

VMR

FS

IGN

NOTE 3

L2

C

RS

GV

3

6

PLF

2

5

C

NOTE 2

1

EM

LS

H

C

D1

FS

F

5

4

L1

NOTE 3

ALS

PS

10

ECON

3

6

8

12

11

Y

Y2

W

Y1

9

IIC

R

TO THERMOSTAT

G

7

TR

1

4

208-240/3/60

0140L00979

REV B

LPS

HPS

LPS

LOW PRESSURE SWITCH

HPS

HIGH PRESSURE SWITCH

BC

BC

3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.

USE

NEC CLASS 2 WIRE.

4. USE COPPER CONDUCTORS ONLY.

2. ACCESSORY ECONOMIZER PLUG ADJACENT

TO BLOWER HOUSING IN RETURN AIR

COMPARTMENT. REMOVE MALE PLUG AND

ATTACH FEMALE PLUG TO THE ECONOMIZER

ACCESSORY.

1. REPLACEMENT WIRE MUST BE THE SAME

SIZE AND TYPE OF

INSULATION AS ORIGINAL.

(USE COPPER CONDUCTOR ONLY).

NOTES

LOW VOLTAGE

LINE VOLTAGE

FIELD WIRING

LOW VOLTAGE

OPTIONAL

HIGH VOLTAGE

FACTORY WIRING

HIGH VOLTAGE

BL

RD

Y1

Y/Y2

YL

W

Y/Y2

BL

G

R

W

NO ECONOMIZER

G

YL

RD

Y/Y2

Y1

PK

WH

W

R

RD

WH

GR

C

R

YL

GR

Y1

G

WH

WITH ECONOMIZER OPTION

C

GR

THERMOSTAT

FIELD WIRING

BL

C

2 STAGE COOLING

TB1

G

R

W

Y

C

TB1

TB1

Y

W

R

G

C

W

Y2

G

R

C

Y1

STAT

STAT

STAT

BL/PK

BLUE WITH PINK STRIP

YL/PK

YELLOW WITH PINK STRIP

GR

GREEN

WIRE CODE

BL

BLUE

PU

PURPLE

PK

PINK

WH

WHITE

BK

BLACK

RD

RED

BR

BROWN

OR

ORANGE

YL

YELLOW

SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER

CURRENT PROTECTION

4. USE COPPER CONDUCTORS ONLY.

VM

5. FOR 208 VOLT TRANSFORMER OPERATION,

MOVE BLACK WIRE FROM TERMINAL

3

TO

TERMINAL

2

ON TRANSFORMER.

Содержание CPG0360451D***B Series

Страница 1: ...ottom utility entry Complies with California NOx emissions standards AHRI Certified ETL Listed Cabinet Features Heavy gauge galvanized steel cabinet with UV resistant powder paint finish Full Perimete...

Страница 2: ...060 60 kW Factory Installed Op7ons 400 400 000 BTU h 025 25 kW 075 75 kW X No OpCons A Down ow Economizer Voltage Supply Fan Drive Type Motors 1 208 230 1 60 4 460 3 60 B Belt Drive 3 208 230 3 60 7 5...

Страница 3: ...Fins per Inch 3 16 3 16 3 16 3 16 Belt Drive Evap Fan Data of Wheels D x W 1 11 x 10 1 11 x 10 Motor Sheave Blower Sheave 1VL40 X AK69 X 1 Belt AX55 AX55 Condenser Fan Coil Quantity of Condenser Fan M...

Страница 4: ...orator Coil Face Area ft 5 4 5 4 5 4 5 4 5 4 Rows Deep Fins per Inch 3 16 3 16 3 16 3 16 3 16 Belt Drive Evap Fan Data of Wheels D x W 1 11 x 10 1 11 x 10 1 11 x 10 Motor Sheave Blower Sheave 1VL40 X...

Страница 5: ...Face Area ft 7 0 7 0 7 0 7 0 Rows Deep Fins per Inch 4 16 4 16 4 16 4 16 Belt Drive Evap Fan Data of Wheels D x W 1 11 x 10 1 11 x 10 Motor Sheave Blower Sheave VL44 X AK66 X 1 Belt AX55 AX55 Condens...

Страница 6: ...3 103 105 Evaporator Coil Face Area ft 7 0 7 0 7 0 7 0 7 0 Rows Deep Fins per Inch 4 16 4 16 4 16 4 16 4 16 Belt Drive Evap Fan Data of Wheels D x W 1 11 x 10 1 11 x 10 1 11 x 10 Motor Sheave Blower S...

Страница 7: ...Data of Wheels D x W 1 11 x 10 1 11 x 10 Motor Sheave Blower Sheave VL44 X AK61 X 1 Belt AX53 AX53 Condenser Fan Coil Horsepower RPM 1 090 1 090 1 090 1 090 Fan Diameter Fan Blades 22 4 22 4 22 4 22 4...

Страница 8: ...Belt Drive Evap Fan Data of Wheels D x W 1 11 x 10 1 11 x 10 1 11 x 10 Motor Sheave Blower Sheave VL44 X AK61 X 1 Belt AX53 AX53 AX53 Condenser Fan Coil Horsepower RPM 1 090 1 090 1 090 1 090 1 075 Fa...

Страница 9: ...t 8 9 8 9 8 9 Rows Deep Fins per Inch 4 16 4 16 4 16 Motor Sheave VL44 x 7 8 VL44 x 7 8 VL44 x 7 8 Blower Sheave Belt AK59x1 AX53 AK59x1 AX53 AK59x1 AX53 Condenser Fan Coil Quantity of Condenser Fan M...

Страница 10: ...1 2 13 462 808 Med 1471 0 10 2 11 454 830 Med 1434 0 2 2 10 448 838 1400 0 20 2 06 440 863 1381 0 3 2 04 436 869 1354 0 30 2 02 432 896 1318 0 4 2 00 424 902 1271 0 40 1 95 416 929 1238 0 5 1 94 406...

Страница 11: ...0 25 1 4 1458 0 63 1139 0 46 782 0 30 1 6 1139 0 52 844 0 36 1 8 844 0 42 Standard Belt Drive Down Shot ESP H2 O Turns Open 0 1 2 3 4 5 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0 2 1596 0 36 1...

Страница 12: ...5 892 Med 1846 0 1 3 14 676 866 Med 1700 0 2 2 75 601 924 1718 0 2 2 81 612 898 1606 0 3 2 61 563 966 1624 0 3 2 67 574 940 1531 0 4 2 48 537 990 1549 0 4 2 54 548 964 1401 0 5 2 32 503 1023 1419 0 5...

Страница 13: ...64 0 86 1426 0 64 1107 0 46 1 6 1446 0 72 1098 0 50 1 8 1099 0 56 Standard Belt Drive Down Shot ESP H2 O Turns Open 0 1 2 3 4 5 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0 2 1891 0 56 1632 0 42...

Страница 14: ...0 5 4 87 612 990 1839 0 6 4 58 582 940 1762 0 6 4 97 626 1008 1782 0 7 4 72 602 968 1688 0 7 5 05 642 1039 2224 0 1 4 73 592 832 T4 2106 0 1 5 14 650 924 T4 2165 0 2 4 79 612 860 2050 0 2 5 26 670 951...

Страница 15: ...1 4 2288 1 38 2009 1 10 1711 0 84 1 6 2032 1 21 1741 0 93 1 8 1776 1 04 Standard Belt Drive Down Shot ESP H2 O Turns Open 0 1 2 3 4 5 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0 2 2210 0 91 2041...

Страница 16: ...1 00 2070 0 80 1898 0 64 0 8 2443 1 29 2251 1 06 2068 0 86 1868 0 71 1 2258 1 17 2040 0 94 1806 0 73 1 2 2021 1 02 High Static Belt Drive Horizontal ESP In W C 0 Turns 1 Turn 2 Turns 3 Turns 4 Turns...

Страница 17: ...85 0 76 0 58 0 37 0 87 0 78 0 59 0 38 0 90 0 81 0 61 0 39 0 94 0 84 0 63 0 41 0 94 0 84 0 64 0 41 T 19 18 15 10 20 18 15 10 20 18 15 10 20 18 15 10 19 18 15 10 18 17 14 9 kW 2 46 2 50 2 58 2 65 2 63 2...

Страница 18: ...9 390 420 444 463 LO PR 105 112 122 130 111 118 129 137 115 123 134 143 121 129 141 150 127 135 147 157 131 140 152 162 85 1350 MBh 35 7 36 4 38 1 40 7 34 9 35 6 37 2 39 7 34 0 34 7 36 3 38 8 33 2 33...

Страница 19: ...0 78 0 59 0 38 0 89 0 80 0 60 0 39 0 92 0 82 0 62 0 40 0 96 0 86 0 65 0 42 0 96 0 86 0 65 0 42 T 19 18 15 10 20 18 15 10 20 18 15 10 20 18 15 10 20 18 15 10 18 17 14 10 kW 3 16 3 22 3 32 3 42 3 39 3 4...

Страница 20: ...53 423 455 480 501 LO PR 108 115 125 134 114 121 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167 85 1800 MBh 47 0 47 9 50 1 53 5 45 9 46 7 49 0 52 2 44 8 45 6 47 8 51 0 43 7 44...

Страница 21: ...0 77 0 58 0 37 0 88 0 79 0 60 0 38 0 91 0 81 0 61 0 40 0 94 0 84 0 64 0 41 0 95 0 85 0 64 0 41 T 20 18 15 10 20 19 15 11 20 19 15 11 20 19 15 11 20 19 15 11 19 17 14 10 kW 4 01 4 09 4 22 4 35 4 31 4 4...

Страница 22: ...63 431 464 490 511 LO PR 105 112 122 130 111 118 129 137 115 123 134 143 121 129 141 150 127 135 147 157 131 140 152 162 85 2250 MBh 61 4 62 6 65 6 69 9 60 0 61 1 64 0 68 3 58 5 59 7 62 5 66 7 57 1 58...

Страница 23: ...58 8 63 6 68 3 S T 0 78 0 69 0 53 0 34 0 80 0 72 0 54 0 35 0 82 0 74 0 56 0 36 0 85 0 76 0 58 0 37 0 88 0 79 0 60 0 38 0 89 0 80 0 60 0 39 T 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 1...

Страница 24: ...52 421 453 479 499 LO PR 105 112 122 130 111 118 129 137 115 123 134 143 121 129 141 150 127 135 147 157 131 140 152 162 85 2400 MBh 72 2 73 6 77 1 82 2 70 5 71 9 75 3 80 3 68 8 70 2 73 5 78 4 67 2 68...

Страница 25: ...arge return and supply openings Install with insulation facing up using the longer screws provided in the literature package RETURN SUPPLY 12 17 7 3 8 11 25 6 1 4 4 7 8 73 1 4 47 1 2 73 13 16 48 3 16...

Страница 26: ...coil electric heat and gas furnace Leave a clearance of 48 on all other sides of the unit for possible compressor removal or service access and to ensure proper ventilation and condenser airflow Do no...

Страница 27: ...installing the unit Duct work dimensions are shown in Roof Curb Installation Instructions Manual Refer to the Roof Curb Installation Instructions for proper curb installation Curbing must be installe...

Страница 28: ...nt structural support before locating and mounting the curb and package unit Duct work must be constructed using industry guidelines The duct work must be placed into the roof curb before mounting the...

Страница 29: ...L 208 240 1 60 0140L00510 REV A YL HPS LPS LPS LOW PRESSURE SWITCH HPS HIGH PRESSURE SWITCH GR HIGH VOLTAGE FACTORY WIRING OPTIONAL HIGH VOLTAGE LOW VOLTAGE FIELD WIRING LINE VOLTAGE LOW VOLTAGE Y2 YL...

Страница 30: ...GH PRESSURE SWITCH GR HIGH VOLTAGE FACTORY WIRING OPTIONAL HIGH VOLTAGE LOW VOLTAGE FIELD WIRING LINE VOLTAGE LOW VOLTAGE Y2 YL BL RD Y1 Y Y2 YL W Y Y2 BL G R W NO ECONOMIZER G YL RD Y Y2 Y1 PK WH W R...

Страница 31: ...WIRE TB1 TB1 TB1 TR TRANSFORMER PU C L2 L2 VMR T2 SUPPLY VOLTAGE 240 1 60 L1 SEE NOTE 2 2 1 3 L1 C T1 YL EM L N C R S COMP H C RCCF CM C 4 VM 2 C F WH H C YL LPS HPS YL PK LPS HPS HIGH PRESSURE SWITCH...

Страница 32: ...STATUS LIGHT CODES ARE AS FOLLOWS THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO STATUS LIGHT 3 BLINKS 6 BLINKS 2 BLINKS 4 BLINKS 5 BLINKS OFF ON 1 BLINK OPEN AUX LIMIT FALSE FLAME...

Страница 33: ...G R 5 7 9 ECON IIC Y1 W Y2 3 6 12 10 8 11 RS ALS PS BAD SWITCH AUX LIMIT OPEN ANTI CYCLE TIMER MAIN LIMIT OPEN STICKING GAS VALVE BAD SWITCH 3 MIN COMP PRESSURE SWITCH PRESSURE SWITCH CHECK CHECK GAS...

Страница 34: ...BAD SWITCH AUX LIMIT OPEN ANTI CYCLE TIMER MAIN LIMIT OPEN STICKING GAS VALVE BAD SWITCH 3 MIN COMP PRESSURE SWITCH PRESSURE SWITCH CHECK CHECK GAS PRESSURE FLAME ROLLOUT FLAME SENSOR GAS VALVE CHECK...

Страница 35: ...STICKING GAS VALVE BAD SWITCH 3 MIN COMP PRESSURE SWITCH PRESSURE SWITCH CHECK CHECK GAS PRESSURE FLAME ROLLOUT FLAME SENSOR GAS VALVE CHECK FUSE ON CONTROL CHECK INPUT POWER REPLACE CONTROL GAS FLOW...

Страница 36: ...W PRESSURE SWITCH CHECK CHECK FUSE ON CONTROL CHECK INPUT POWER CHECK TRANSFORMER TR ALS COMP COMPONENT LEGEND COMPRESSOR EM IIC IGN GND FS GV C F FUSE FC EVAPORATOR MOTOR FLAME SENSOR EQUIPMENT GROUN...

Страница 37: ...URE SWITCH LPS HPS LPS 460 575 3 60 0140L00871 REV B 4 1 TR 7 G TO THERMOSTAT R IIC 9 Y1 W Y Y2 11 12 8 6 3 ECON 10 PS ALS NOTE 3 L1 4 5 F FS D1 C H LS VM EM 1 NOTE 2 C 5 2 PLF 6 3 GV RS C L2 NOTE 3 I...

Страница 38: ...SOR BAD SWITCH GAS VALVE REPLACE CONTROL GAS FLOW PRESSURE SWITCH CHECK CHECK FUSE ON CONTROL CHECK INPUT POWER CHECK TRANSFORMER TR ALS COMP COMPONENT LEGEND COMPRESSOR EM IIC IGN GND FS GV C F FUSE...

Страница 39: ...wnflow Economizer 3 6 tons DNSQRRND36B Downflow Square to Round Adapter 16 Round 3 tons DNSQRRND4872B Downflow Square to Round Adapter 18 Round 4 6 tons HA 02 High Altitude Kit All Models HSKT036B Hig...

Страница 40: ...PG36 72 Goodman Manufacturing Company L P reserves the right to discontinue or change at any time specifications or designs without notice or without incurring obligations 2012 Goodman Manufacturing C...

Отзывы: