SS-CPG36-72
www.goodmanmfg.com
37
w
irinG
d
iaGram
—
CPG036/480454B
—
CPG072*4B/7B (460v/ 575v B
elt
d
rive
)
Wiring
is
subject
to
change.
Al
wa
ys
refer
to
the
wiring
diag
ram
or
the
unit
for
the
most
up-to-da
te
wiring
.
⚠
w
arnin
G
High
Voltage:
Disconnect
all
power
bef
or
e
ser
vicing
or
installing
this
unit.
Multiple
power
sour
ces
ma
y
be
pr
esent.
F
ailur
e
to
do
so
ma
y
cause
pr
operty
damage,
per
sonal
injur
y,
or
dea
th.
⚡
BK
OR
C
F
BL
NOTE 3
SEE
GR
W H
W1
RD
R
BL
C
Y1
YL
Y2
G
TO THERMOSTAT
YL/PK
BL/PK
W H
LPS
HPS
RD
BR
RD
FC
RD
OR
VM
BK
IGN
FS
NOTE 3
SEE
PU
GR
GV
GAS VALVE
(ALT.) HONEYW ELL
BL
BL
GV
GAS VALVE
W. R.
PU
PU
MV
MV
YL
BL
L2
BL
BL
UN
US
ED
COOL
HE
AT
GR
BL
575
575/3/60
460/3/60
SEE NOTE 4
POWER SUPPLY
GR
S2
S1
BL
OR
BK
OR
L3
L2
L1
OR
RD
BK
BC
C
T3
T1
T2
PK
TB1
SMOKE/FIRE
DETECTOR
REPLACES JUMPER
W IRE
BR
OR
BK
460/575
TR
240
C
460
BL
BL
TR
24V
BL
VMR
3
1
2
WH
RD
EM
OR
BK
RD
OR
ALS
RS
YL
3
6
PLF
NOTE 2
2
1
4
5
PS
PU
YL
PU
YL
GR
BL
YL
YL
RD
DI
RD
YL
FS
BR
L1
WH
4
5
6
2
3
1
RD
RD
RD
PU
BL
ECON
11
8
12
9
7
10
GR
W H
LS
RD
RD
BK
BR
CM
COMP
PU
T1
T2
T3
BK
BK
OR
RD
BL
BL
L2
L1
C
RD
BK
YL
PU
BK
T2
T1
IIC
YL
GR
BK
YL
L3
OR
RD
T3
GND
460-575/3/60
0140L00871 REV B
SEE UNIT RATING PLATE FOR TYPE AND
SIZE OF OVER CURRENT PROTECTION.
SUPPLY VOLTAGE
460-575/3/60
YL
YELLOW
OR
ORANGE
BR
BROWN
RD
RED
BK
BLACK
WH
WHITE
PK
PINK
PU
PURPLE
BL
BLUE
WIRE CODE
GR
GREEN
YL/PK
YELLOW WITH PINK STRIP
BL/PK
BLUE WITH PINK STRIP
STAT
STAT
STAT
Y1
C
R
G
Y2
W
C
G
R
W
Y
TB1
TB1
C
Y
W
R
G
TB1
2 STAGE COOLING
C
BL
THERMOSTAT
FIELD WIRING
GR
C
WITH ECONOMIZER OPTION
WH
G
Y1
GR
YL
R
C
GR
WH
RD
R
W
WH
PK
Y1
Y/Y2
RD
YL
G
NO ECONOMIZER
W
R
G
BL
Y/Y2
W
YL
Y/Y2
Y1
RD
BL
RD
BK
OR
BC
BC
HIGH PRESSURE SWITCH
HPS
LOW PRESSURE SWITCH
LPS
HPS
LPS
460-575/3/60 0140L00871 REV B
4
1
TR
7
G
TO THERMOSTAT
R
IIC
9
Y1
W
Y
Y2
11
12
8
6
3
ECON
10
PS
ALS
NOTE 3
L1
4
5
F
FS
D1
C
H
LS
VM
EM
1
NOTE 2
C
5
2
PLF
6
3
GV
RS
C
L2
NOTE 3
IGN
FS
VMR
IIC
BC
VMR
3
1
3
L1
C
L1
COMP
T1
T1
T2
T3
T2
FC
C
T3
CM
L3
L2
C
L3
L2
BC
BLOWER CONTACTOR
BC
INDOOR BLOWER RELAY
IBR
AUXILLARY LIMIT SWITCH
FEMALE PLUG/CONNECTOR
INTEGRATED IGNITION CONTROL
CM
CONDENSER MOTOR
LS
LIMIT SWITCH
VENT MOTOR RELAY
VENT MOTOR
PRESSURE SWITCH
TERMINAL BLOCK (24V SIGNAL)
ROLLOUT SWITCH
VMR
VM
PS
PLF
TB1
RS
FAN CAPACITOR
CONTACTOR
GAS VALVE
IGNITOR
EQUIPMENT GROUND
FLAME SENSOR
EVAPORATOR MOTOR
FC
FUSE
F
C
GV
FS
GND
IGN
IIC
EM
COMPRESSOR
COMPONENT LEGEND
COMP
ALS
OPTIONAL HIGH
VOLTAGE
HIGH VOLTAGE
FIELD WIRING
LOW VOLTAGE
LINE VOLTAGE
FACTORY WIRING
LOW VOLTAGE
TR
TRANSFORMER
NOTES
CHECK
-
CHECK INPUT POWER
CHECK FUSE ON CONTROL
CHECK
PRESSURE SWITCH
GAS FLOW
REPLACE CONTROL
GAS VALVE
BAD SW ITCH
FLAME SENSOR
AUX. LIMIT OPEN
FLAME ROLLOUT
GAS PRESSURE
PRESSURE SWITCH
3 MIN. COMP.
BAD SW ITCH
STICKING GAS VALVE
MAIN LIMIT OPEN
ANTI-CYCLE TIMER
CHECK
EQUIP. STATUS
NO POWER OR
SWITCH
OPEN
SWITCH
OPEN ROLLOUT
IGNITION FAILURE
OPEN AUX. LIMIT
STATUS LIGHT
2 BLINKS
1 BLINK
ON
OFF
COMPRESSOR
OUTPUT DELAY
5 BLINKS
4 BLINKS
6 BLINKS
3 BLINKS
INTERNAL CONTROL
NORMAL OPERATION
PRESSURE SWITCH
PRESSURE SWITCH CLOSED
WITHOUT INDUCER ON
OPEN LIMIT SWITCH
FALSE FLAME SENSED
THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:
INSTALLER/SERVICEMAN
1. REPLACEMENT WIRE MUST BE THE SAME
SIZE AND TYPE OF INSULATION AS ORIGINAL.
(USE COPPER CONDUCTOR ONLY).
2. ACCESSORY ECONOMIZER PLUG ADJACENT
TO BLOWER HOUSING IN RETURN AIR
COMPARTMENT. REMOVE MALE PLUG AND
ATTACH FEMALE PLUG TO THE ECONOMIZER
ACCESSORY.
4. USE COPPER CONDUCTORS ONLY.
USE NEC CLASS 2 WIRE.
3. L1 AND L2 ON IIC CONTROL IS 24V INPUT.