SYSTEM OPERATION

6

Safety

Please adhere to the following warnings and cautions when 

installing, adjusting, altering, servicing, or operating the 

furnace.

T

O P

REVE

NT P

ERS

ONAL 

I

N

JUR

Y O

R

 D

E

ATH D

UE

 TO 

IM

P

R

OP

ER

 

I

N

S

TALLAT

I

ON,

AD

JUS

T

ME

NT, ALT

ER

AT

I

ON, 

SERVI

C

E

 O

R

 

M

A

I

NT

E

NANC

E

RE

F

ER

 TO TH

IS

M

AN

U

AL. 

F

O

R

 ADD

I

T

I

ONAL A

SSIS

TANC

E

 O

R

 

I

NFO

RM

AT

I

ON, CON

SU

LT A

QU

AL

I

F

IE

I

N

S

TALL

ER

SERVI

C

E

 AG

E

NCY O

R

 TH

E

 GA

S

 

SU

PPL

IER

.

WARNING

WARNING

T

O P

REVE

NT PO

SSI

BL

E

 P

R

OP

ER

TY DA

M

AG

E

, P

ERS

ONAL 

I

N

JUR

Y O

R

 D

E

ATH

D

UE

 TO 

E

L

E

CT

RI

CAL 

S

HOC

K

, TH

E

 F

UR

NAC

E

 

MUS

T B

E

 LOCAT

E

D TO P

R

OT

E

CT

TH

E

 

E

L

E

CT

RI

CAL CO

M

PON

E

NT

S

 F

R

O

M

 

W

AT

ER

.

Charge (ESD) Precautions
NOTE: 

Discharge your body’s static electricity before touching 

unit. An electrostatic discharge can adversely affect electrical 

components.
Use the following precautions during furnace installation 

and servicing to protect the integrated control module from 

damage. By putting the furnace, the control, and the person 

at the same electrostatic potential, these steps will help 

avoid exposing the integrated control module to electrostatic 

discharge. This procedure is applicable to both installed and 

uninstalled (ungrounded) furnaces.
1.  Disconnect all power to the furnace. Do not touch the 

integrated control module or any wire connected to the 

control prior to discharging your body’s electrostatic  

charge to ground.

2.  Firmly touch a clean, unpainted, metal surface of the 

furnace near the control. Any tools held in a  person’s 

hand during grounding will be discharged.

3.  Service integrated control module or connecting wiring 

following the discharge process in Step 2. Use caution 

not to recharge your body with static electricity; (i.e., do 

not move or shuffle your feet, do not touch ungrounded 

objects, etc.). If you come in contact with an ungrounded 

object, repeat Step 2 before touching control or wires.

4.  Discharge any static electricity from your body to ground 

before removing a new control from its container. Follow 

Steps 1 through 3 if installing the control on a furnace. 

Return any old or new controls to their containers before 

touching any ungrounded object.

Product Application

This product is designed for use as a residential home gas 

furnace. It is 

not

 designed or certified for use in mobile home, 

trailer, or recreational vehicle applications.

In the U.S.A., this furnace can be used in the following non-industrial 

commercial applications: Schools, Office buildings, Churches, Retail 

stores, Nursing homes, Hotels/motels, Common or office areas.  In 

all applications, the furnace must be installed per the installation 

instructions.

Goodman

®

 brand GMVS96*U and Amana

®

  brand  AMVS96*U  

furnaces are ETL certified.  All *MVS96*U furnaces are built 

for use with Natural gas only & may not be converted for use 

with LP gas.
Goodman

®

 brand GMVS96*U and  Amana

®

  brand AMVS96*U  

high efficiency furnaces are dual certified. Dual certification 

means that the combustion air inlet pipe is optional and the 

furnace can be vented as a:
• 

  Non-direct vent (single pipe) central forced air furnace 

in which combustion air is taken from the installation 

area or from air ducted from the outside or,

• 

 Direct vent (dual pipe) central forced air furnace in 

which all combustion air supplied directly to the furnace 

burners through a special air intake system outlined in 

this manual and the installation instructions.

To ensure proper installation, operation and servicing, 

thoroughly read the installation and service manuals 

for  specifics  pertaining  to  the  installation,  servicing  and 

application of this product. 

WARNING

P

O

SSI

BL

E

 P

R

OP

ER

TY DA

M

AG

E

, P

ERS

ONAL 

I

N

JUR

Y O

R

 D

E

ATH D

UE

 TO F

IRE

,

EX

PLO

SI

ON, 

SM

O

KE

S

OOT, COND

E

N

S

TA

I

ON, 

E

L

E

CT

RI

CAL 

S

HOC

K

 O

R

 CA

R

BON

M

ONO

XI

D

E

 

M

AY 

RESU

LT F

R

O

M

 

IM

P

R

OP

ER

 

I

N

S

TALLAT

I

ON, 

RE

PA

IR

, OP

ER

AT

I

ON,

O

R

 

M

A

I

NT

E

NANC

E

 OF TH

IS

 P

R

OD

U

CT.

WARNING

T

O P

REVE

NT P

R

OP

ER

TY DA

M

AG

E

, P

ERS

ONAL 

I

N

JUR

Y O

R

 D

E

ATH D

UE

 TO F

IRE

,

DO NOT 

I

N

S

TALL TH

IS

 F

UR

NAC

E

 

I

N A 

M

OB

I

L

E

 HO

ME

, T

R

A

I

L

ER

, O

R

 

RE

C

RE

AT

I

ONAL

VE

H

I

CL

E

.

To ensure proper furnace operation, install, operate, maintain 

and service the furnace in accordance with the installation, 

operation and service instructions, all local building codes 

and ordinances. In their absence, follow the latest edition of 

the National Fuel Gas Code (NFPA 54/ANSI Z223.1), and/or 

CAN/CGA B149 Installation Codes, local plumbing or waste 

water codes, and other applicable codes.

EMI Filter (Electromagnetic Interference Filter)

All *MVS96*U furnaces must have an EMI Filter installed. 

Early  production  furnaces  will  require  the  EMI  filter  to  be 

field installed at the time of furnace installation as furnaces 

are shipped without this component. The kit (EMIULN-1) is 

available from your furnace distributor at no cost. 
The purpose of the EMI Filter is to reduce electromagnetic
interference between the furnace and other electrical devices.

Содержание AMVS960603BU AA

Страница 1: ...serviced only by a qualified service technician who is familiar with the safety procedures required in the repair and who is equipped with the proper tools parts testing instruments and the appropriat...

Страница 2: ...arts testing in struments and the appropriate service manual REVIEWALL SERVICEINFORMATIONINTHEAPPROPRIATESERVICE MANUAL BEFORE BEGINNING REPAIRS OUTSIDE THE U S call 1 713 861 2500 Not a technical ass...

Страница 3: ...El mon xido de carbono puede causar enfermedades severas como da o cerebral permanente muerte Las emisiones de mon xido de carbono pueden circular a trav s del aparato cuando se opera en cualquier mo...

Страница 4: ...ENTIFICATION 4 NOMENCLATURE The model and manufacturing number are used for positive identification of component parts used in manufacturing Please use these numbers when requesting service or parts i...

Страница 5: ...s Steel tubular heat exchanger 115 volt silicon nitride igniter Left or right gas entry Line voltage EAC terminal GMVS96 U GMVS960603BU AA GMVS960805CU AA Goodman Brand 96 Ultra Low NOx Gas Furnace 1...

Страница 6: ...the U S A this furnace can be used in the following non industrial commercial applications Schools Office buildings Churches Retail stores Nursing homes Hotels motels Common or office areas In all app...

Страница 7: ...T IN PROPERTY DAMAGE EQUIPMENT DAMAGE PERSONAL INJURY OR DEATH Condensate Drain Lines and Drain Trap Acondensing gas furnace achieves its high level of efficiency by extracting almost all of the heat...

Страница 8: ...ply pressures must be maintained within the ranges specified below The supply pressure must be constant and available with all other household gas fired appliances operating The minimum gas supply pre...

Страница 9: ...l altitudes the air temperature rise must be within the range listed on the the Specification Sheet applicable to your model for the fuel used Manifold pressure adjustments and combustion analysis are...

Страница 10: ...all after the power is turned on will run the outdoor unit at full capacity until the call is removed Use this mode for charging If system is running low stage cooling just cycle power and provide a c...

Страница 11: ...arget Runtime the temporary heat pump hold will be completely removed and the heat pump will become the primary heat source again if it fails to do so the strike count against the furnace will be rese...

Страница 12: ...mps up to full cooling demand airflow by first stepping up to 50 of the full demand for 30 seconds The motor then ramps to 100 of the required airflow A one 1 minute OFF delay at 100 of the cooling ai...

Страница 13: ...D ehum Optional Optional Optional if feature supported by thermostat L1 L2 INDOOR BOARD TERMINAL CONNECTIONS OUTDOOR BOARD TERMINAL CONNECTIONS OUTDOOR TRANSFORMER 24V AC 240V GROUNDRECOMMENDED FIELDP...

Страница 14: ...Refer to the low voltage wiring diagrams for additional wiring details Dehumidistat close on humidity rise R C G Y D ehum Dehumidistat close on humidity rise Figure 41 Fossil Fuel Applications This f...

Страница 15: ...105 C All line voltage wire splices must be made inside the furnace junction box Auxiliary Alarm Switch The control is equipped with a 24VAC Aux Alarm to be used for a condensate switch install desig...

Страница 16: ...sfully been completed the user will have access to system information once in range Option 2 Remove the furnace door ensure the control has power and then read the 3 digits The code will temporarily r...

Страница 17: ...scroll through Menus L6F Lm Cr Sr and rFd 4 Press and release the Center Button The center button is used to enter menus and make selections within menus 5 What will be displayed is the currently sele...

Страница 18: ...d increments Gas Heat Trim Factor Option Menu Gas Heat airflow may be trimmed from 10 to 10 in 2 increments Gas Heat Stage Multiplier Menu CFM This menu allows adjustment of the low fire CFM multiplie...

Страница 19: ...or otherwise trap condensate Use longest radius fittings possible If using 3 venting make the transition from 2 to 3 as close as practically possible Make sure there is no flue gas recirculation into...

Страница 20: ...are for vertical or horizontal termination of the combustion air inlet and the exhaust vent pipes on Category IV gas fired condensing furnaces The DCVK 30 kit can be used for 3 diameter pipe systems...

Страница 21: ...DRAFT AND CIRCULATION BLOWERS The bearings in the induced draft blower and circulator blower motors are permanently lubricated by the manufacturer No further lubrication is required Check motor windin...

Страница 22: ...2 164 327 655 1636 37 97 195 486 12 75 150 300 600 1500 38 23 47 95 189 474 13 69 138 277 555 1385 39 92 185 462 14 64 129 257 514 1286 40 22 45 90 180 450 15 60 120 240 480 1200 41 176 439 16 56 113...

Страница 23: ...t As the external static pressure goes up the temperature rise will also increase Consult the proper tables for tempera ture rise limitation BTU HR Calculation Example The unit being tested takes 40 s...

Страница 24: ...SERVICING 24 GAS VALVE BURNER ASSEMBLY PRESSURE TRANSDUCER INTEGRATED CONTROL BOARD CONTROL TRANSFORMER PRESSURE SWITCHES VENT PIPE CONNECTION COMBUSTION AIR CONNECTION DRAFT INDUCER Component I D...

Страница 25: ...wires must be replaced replace with AWM 105 C 2 64 thick insulation of the same gauge or its equivalent CHECKING THERMOSTAT WIRING DISCONNECT ALL POWER BEFORE SERVICING WARNING 1 Remove the blower co...

Страница 26: ...motor reinstall blower compartment door 6 Turn on electrical power and verify proper unit operation DISCONNECT ALL POWER BEFORE SERVICING WARNING CHECKING DUCT STATIC The maximum and minimum allowabl...

Страница 27: ...erature rise Decrease blower speed to increase temperature rise Refer to Circulator Blower Speed section in the Product Design section of this manual for speed changing details Temperature rise is rel...

Страница 28: ...uced draft blower This voltage to the IBD will vary between furnace models and is dependent on what percentage of maximum fire is being called for The power wires are colored red white and black A gre...

Страница 29: ...e etc and or consult with local gas utility WARNING HIGH VOLTAGE DISCONNECT ALL ELECTRICAL POWER AND SHUT OFF GAS SUPPLY BEFORE SERVICING OR INSTALLING THIS UNIT MULTIPLE POWER SOURCES MAY BE PRESENT...

Страница 30: ...E PERSONAL INJURY OR DEATH 6 Turn on gas to furnace and check for leaks If leaks are found repair and then reinstall burner compartment door 7 Turn on electrical power and verify proper unit operation...

Страница 31: ...ition control No voltage Check transformer room thermostat and wiring If you have 24 volts coming off the transformer but receive approximately 13 volts on the terminal board between C and R check for...

Страница 32: ...utively satisfy the thermostat under the set target time for this number of cycles the system will transition to the heat pump for primary heating dP Menu is enabled if the CF menu is set to 6 this pe...

Страница 33: ...ge non communicating units AC Compressor Cooling Single Stage single stage non comm units AC1 Compressor Cooling Low Stage communicating units AC2 Compressor Cooling High Stage communicating units dHU...

Страница 34: ...a set is correct for the specific model re populate data using correct memory card if required Furnace operates at reduced performance Airflow delivered is less than expected Circulator blower motor i...

Страница 35: ...r Furnace fails to operate 1 Analog Pressure Error Blocked Vent Error Need to check the APS Sensor or its connection if this error is occurred The failure conditions occur as per the following for 5 s...

Страница 36: ...essure switch circuit is closed at start of heating cycle Low stage pressure switch contacts sticking Short in pressure switch circuit wiring Replace low stage pressure switch Repair short in wiring I...

Страница 37: ...erify and correct unit ground wiring if needed Check igniter output from control replace if necessary Furnace fails to operate on high stage furnace operates normally on low stage Induced draft blower...

Страница 38: ...ch condensate switch open Check evaporator drain pan trap piping Fault Code Recall Accessing the furnace s diagnostic menu provides access to the last six faults detected by the furnace Faults are sto...

Страница 39: ...ED CONTROL PK C USE COPPER CONDUCTORS ONLY AT LEAST 105 IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF 3 IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLA...

Страница 40: ...contact us Amana Brand Products http www amana hac com about us contact us You can also scan the QR code on the right for the product brand you purchased to be directed to the feedback page GOODMAN B...