SYSTEM OPERATION
15
115 Volt Line Connection of Electronic Air
Cleaner
HIGH VOLTAGE !
T
O
AVOID
PERSONAL
INJURY
OR
DEATH
DUE
TO
ELECTRICAL
SHOCK
,
DISCONNECT
ELECTRICAL
POWER
BEFORE
SERVICING
OR
CHANGING
ANY
ELECTRICAL
WIRING
.
WARNING
The accessory load specifications are as follows:
EAC
1.0 Amp maximum at 120 VAC
The furnace integrated control module is equipped with
a line voltage accessory terminal for controlling power
to an optional field supplied electronic air cleaner or any
device required to operate inparallel with a circulating
fan demand.
To connect an electronic air cleaner using the line volt-
age EAC terminal:
•
Turn OFF power to the furnace before installing any
accessories.
•
Follow the air cleaner manufacturers’ instructions
for locating, mounting, grounding, and controlling
accessories. Utilize 1/4” quick connect terminals to
make accessory wiring connections to the furnace
integrated control module.
•
Connect the hot terminal utilized for accessory operation
to the EAC terminal and the neutral side of power to
NEUTRAL bus on the integrated furnace control or the
neutral connection in the furnace junction box.
•
All field wiring must conform to applicable codes.
•
Connections should be made as shown.
•
If it is necessary for the installer to supply additional line
voltage wiring to the inside of the furnace, the wiring
must conform to all local codes, and have a minimum
temperature rating of 105°C.
•
All line voltage wire splices must be made inside the
furnace junction box.
Auxiliary Alarm Switch:
The control is equipped with a 24VAC Aux Alarm to be
used for a condensate switch install (designated by
“Condensate” on the control).
These contacts could
also be used with compatible CO
2
sensors or Fire Alarms.
By default, an AUX switch is normally closed and opens
when the water level in the evaporator coil base pan
reaches an undesirable level. The control will respond
by turning off the outdoor condensing unit and display
EEd. If the AUX switch is detected closed for 30 seconds,
normal operation resumes and error messages are no
longer displayed.
CoolCloudHVAC Phone Application – General Information
Examples of CoolCloudHVAC Phone Application
Screens
NOTE: Actual screen may look different based on the
device being used.
This furnace is Bluetooth ready and functions with a
custom phone application designed to improve the
setup / diagnostic experience of the installing contrac-
tor. Users can see specific model information, review
active diagnostic error codes, observe system status
during operation, make system menu adjustments
such as the target runtime, add site visit notes and run
system testing of all operational modes (heat / cool /
fan) directly from the phone. The phone application is
also capable of directly updating the furnace software
anytime updates are available (the application will
automatically notify the user if updates are available).
Software update time could take approximately 15
minutes to complete. The phone must remain with-
in Bluetooth range for only the download step of an