2
INDEX
TO THE INSTALLER
....................................................... 2
TO THE OWNER
.............................................................. 2
SHIPPING INSPECTION
................................................. 2
SAFETY INSTRUCTIONS
................................................ 2
ORDERING PARTS
......................................................... 5
GENERAL INFORMATION
............................................... 5
TRANSPORTATION DAMAGE
........................................ 5
PRE-INSTALLATION CHECKS
........................................ 6
UNIT INSTALLATION
....................................................... 6
All Installations ........................................................... 6
Ground Level Installations Only
................................. 6
Rooftop Installations Only
..........................................
7
Roof Curb Installations Only
......................................
7
Rigging Details .................................................................
7
Gas Piping ........................................................................
8
LP Conversion
............................................................
8
High Altitude Derate (U.S. Installations Only)
...........
8
Piping .........................................................................
8
Electrical Wiring
................................................................ 10
High Voltage Wiring
................................................. 11
Thermostat Controls
................................................. 11
Low Voltage Wiring
.................................................. 11
Internal Wiring
............................................................ 11
Circulating Air and Filters
.................................................. 11
Airflow Conversion
.................................................... 11
Horizontal Air Flow
..................................................... 12
Ductwork
.................................................................... 12
Filters ......................................................................... 12
Venting
.............................................................................. 12
Installation - Flue Hood Exhaust
................................ 12
Installation - Combustion Air Intake Hood
.................. 12
Condensate Drain
............................................................. 13
Condensate Drain Connection
................................... 13
Heat Pump Operation
....................................................... 13
Heat Pump Mode Operation Sequence of Operation
14
Heat Pump to Gas Heat Sequence of Opeation
........ 14
Outdoor Thermostat
................................................... 14
Optional Outdoor Thermostat (OTDFPKG-01)
........... 14
Normal Sequences Of Operation
..................................... 14
Heating Cycle (Natural Gas/ LP)
................................ 14
Defrost Cycle
............................................................. 15
Cooling ....................................................................... 15
Fan Only
................................................................... 15
Air flow Measurement and Adjustment
...................... 16
Air Flow Adjustments For Indoor Blower Motor
.......... 16
Start-up, Adjustments, and Checks
.................................. 16
Heating Start-up ( Natural Gas / LP)
.......................... 16
Cooling Start-up ......................................................... 19
Suggested Field Testing Troubleshooting
......................... 19
Cooling Start-up ......................................................... 21
Checking Subcooling
................................................. 21
Checking Superheat
.................................................. 21
TROUBLESHOOTING
..................................................... 22
MAINTENANCE
............................................................... 24
ACCESSORIES AND FUNCTIONAL PARTS
................... 25
APPENDIX
....................................................................... 26
TROUBLESHOOTING
..................................................... 26
Ignition Control Diagnostic Indicator Chart
................
27
Heating Timing Chart
.................................................
27
Cooling/heat pump Timing Chart
...............................
27
UNIT DEMENSIONS
........................................................
28
WIRING DIAGRAMs
......................................................... 29
BLOWER PERFORMANCE DATA
................................... 31
START-UP CHECKLIST
................................................... 33
TO THE INSTALLER
Before installing this unit, please read this manual to
familiarize yourself on the specific items which must be
adhered to, including maximum external static pressure to
unit, air temperature rise, minimum or maximum CFM and
motor speed connections.
IMPORTANT NOTE:
If a crankcase heater is used, the unit
should be energized 24 hours prior to compressor start up
to ensure crankcase heater has sufficiently warmed the
compressor. Compressor damage may occur if this step is
not followed.
TO THE OWNER
A warranty certificate is provided with the unit. Read the
warranty carefully and note what is covered. Keep the
warranty certificate in a safe place so you can find it when
necessary.
SHIPPING INSPECTION
Upon receiving the unit, inspect it for damage from
shipment. Claims for damage, either shipping or concealed,
should be filed immediately with the shipping company.
Check the unit model number, specifications, electrical
characteristics and accessories to determine if they are
correct. In the event an incorrect unit is shipped, it must be
returned to the supplier and must NOT be installed. The
manufacturer assumes no responsibility for installation of
incorrectly shipped units.
SAFETY INSTRUCTIONS
The following symbols and labels are used throughout
this manual to indicate immediate or potential safety
hazards. It is the owner’s and installer’s responsibility to
read and comply with all safety information and instructions
accompanying these symbols. Failure to heed safety
information increases the risk of personal injury, property
damage, and/or product damage.
Содержание 209319576
Страница 34: ...34 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 35: ...35 THIS PAGE IS INTENTIONALLY LEFT BLANK...