![Good Will Instrument GKP-2302 Скачать руководство пользователя страница 215](http://html1.mh-extra.com/html/good-will-instrument/gkp-2302/gkp-2302_user-manual_2242923215.webp)
7.2 When a Failure is Suspected
201
Category
Symptom
Possible Cause
Necessary Actions
The output
overvoltage
error occurs for
an inductive
load (e.g.,
transformer).
An abrupt change in
the output current
generated a back
electromotive force.
When the output is off or the
peak current limiter is activated,
the load current may change
abruptly, which generates a back
electromotive force to cause the
output overvoltage error. To
avoid the abrupt current change,
reduce the setting value of the
peak current limiter sufficiently
for a smaller output current, or
conversely set it to a sufficiently
large value to disable the limiter
to be activated, or sufficiently
reduce the amplitude before
turning off the output.
Memory
function-
related
problem
The memory
cannot be
recalled.
The output is on.
The output on state does not
allow the recall. Turn the output
off.
Sequence/
Simulation-
related
problem
The Sequence
cannot be
started.
The output is off.
Turn on the output, then start
the sequence.
The specified
Step Time is
exceeded.
The Stop Phase is
enabled.
When the stop phase setting is
active, the execution waits for
the Step Time that was set pass,
and keeps the output setting
until it reaches the Stop Phase
that was set, and then transitions
to the next step. As the result,
the actual step time is longer
than the set Step Time. To move
to the next step immediately
after the Step Time, disable the
Stop Phase.
Содержание GKP-2302
Страница 15: ...1 1 OUTLINE 1 1 Overview 2 1 2 Features 2...
Страница 28: ...GKP 2302 User Manual 14 Nothing is connected to the output terminal...
Страница 60: ......
Страница 186: ......
Страница 187: ...173 5 DESCRIPTION OF SCREEN AND MENU 5 1 Screen Configuration 174 5 2 Menu Composition 177...
Страница 195: ...181 6 REMOTE CONTROL 6 1 Communication Interface 182 6 2 Remote Local State Switching 188...
Страница 203: ...189 7 TROUBLESHOOTING 7 1 Error Messages and Error Handling 190 7 2 When a Failure is Suspected 196...
Страница 216: ......
Страница 222: ......
Страница 245: ...9 34 Outline Dimensional Drawing 231 9 34 Outline Dimensional Drawing Figure 9 2 Outline Dimensional Drawing...