5 Annex
DC155
Gönnheimer Elektronic GmbH
phone.: +49 (6321) 49919-0, fax: -41
Email: [email protected]
8.4
Type Code (Configuration example)
DC155
.x .x .x .x .x .x .x
Analog input:
No analog input
One 4...20mA input
.0
.1
Analog output:
No analog output
0/4...20mA output
PID controlled analog output
.0
.1
.2
NAMUR input:
NAMUR input
Two NAMUR inputs
.0
.1
Pt100 input:
No Pt100 input
One Pt100 input
.0
.1
Interface:
No interface
TTY sender an receiver
RS485
.0
.3
.5
Protocol:
No Protocol
Modbus
.0
.2
Separate power supply for analog output and TTY / RS485:
No separate power supply terminal
With separate power supply terminal
.0
.1
8.5
Batteries and battery replacement
Only Gönnheimer EB350.1 batteries must be used. The exchange of the batteries is permitted in explosive areas of zone 1
and 2.
The positive pole (red) and the negative pole (blue) of the battery must be connected in accordance with the imprint on the
back of the housing.
8.6
Ex-technical terminal limit values
The intrinsically safe terminal limit values are specified in the EU type examination certificate
BVS 18 ATEX E 040 / IECEx BVS 18.0031.