DC155
5 Annex
Page 19
Gönnheimer Elektronic GmbH
phone.: +49 (6321) 49919-0, fax: -41
Email: [email protected]
4
Starting, parameter default settings
The following table shows the parameter settings defaults. These basic defaults exist on each DC155. The
parameter count can increase by any additional option.
1. Level 2. Level
Parameter
Value
Comment
Language
German, English, French,
Dutch
English
Structure
Units
Type (mass, volume)
Setpoint:
Sum counter:
Flow:
mass
000000 kg
000000000 kg
0000000 kg/s
Dosing method
Flow
Level
Flow
Devices with analog output
Input (Flow)
Namur, 24V,
0/20mA, 4/20mA
24V input
Type of the input signal
Impulse value
Max. Flow
1.000000kg
0 kg/s
Digital flow sensor:
Namur or 24V input
Flow at 20mA
Creeping suppression
0 kg/s
0 kg/s
Analog flow sensor:
0/20mA or 4/20mA
Input (Level)
0/20mA or 4/20mA
rising / falling
Level at 20mA
4/20mA
sinking
0 kg
Devices with analog output:
Level rises or falls while dosing
Output
Dig. output 1
Dig. output 2
Dig. output 3
No function
No function
No function
Function of the output
Dig. output 1
Dig. output 2
Dig. output 3
Normally closed
Normally closed
Normally closed
Polarity of the output
"normally closed" or
"normally open"
Type of Analog Output
Function of Analog Output
4/20 mA
No function
Devices with analog output
Flow monitoring Active / Inactive
Inactive
Not, if Dosing method = Level
Temperature
Compensation
Active / Inactive
Reference Temperature
Coeff. of expansion
Temperature monitoring
Minimum value
Maximum value
Default value
Stop Dosing
Error signal
Inactive
20°C
0.000E-3 1/K
No
-20°C
99°C
20°C
No
No
Devices with Pt100 input
Parameters for temperature monitoring:
Display
Upper display
Lower display
Setpoint
Actual value
Serial Interface
Baud rate
Bits
Parity
Print protocol
9600
8
No
No
Devices with TTY/RS485
- without modbus protocol
Parity
Swap High/Low byte
Device address
No
No
1
Devices with TTY/RS485
- with modbus protocol
Key locking
Enable / Disable
Keys enabled
All keys are active
Содержание DC 155
Страница 1: ...User s manual Dosing Controller DC 155 Manual DC155 Rev C03 1 ...
Страница 18: ...Page 18 4 manual DC155 Gönnheimer Elektronic GmbH phone 49 6321 49919 0 fax 41 Email info goennheimer de ...
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 39: ......
Страница 40: ......
Страница 41: ......