Installation
The fitting and handling of the power supply must be carried out by authorised personnel in the absence of
electrical current.
Install the power supply in a dry, protected and ventilated location. Make sure that the vents are not obstructed.
Use a DIN 46277 rail for fastening ( elements).
4
Note that current regulations stipulate that the power supply must be protected by a circuit breaker.
To prevent electric shock, do not remove the protective cover without first disconnecting the power supply. Replace
it once all connections have been made.
Connect the wires to the installation terminals following the instructions in the diagrams.
C
A.
Terminal/telephone Bus connection
terminals.
B.
Door panel Bus connection terminals.
C.
Protective cover for the current input.
D.
Current input connection terminals.
E.
Detail of the current input terminals
without protective cover.
N
L
12240141
V01
OUTPUT
M
GOLMAR S.A.
C/ Silici, 13
08940 - SPAIN
MADE IN CHINA
BUS 30V 2V 0.5A
±
0.8A 50-60Hz
INPUT ~100-240V
FA-G2+/LITE
PL
BUS BUS
N
L
BUS(M) BUS(PL)