108
PLATEA TELEPHONE DESCRIPTION
D
escription of the T-730/R5 telephone.
F
unction push button.
a
d
c
e
b
g
e
f
a.
b.
c.
d.
e.
f.
g.
Telephone handset.
Speaker grille.
Microphone hole.
Subjection hole.
Telephone cord connectors.
Function push button.
Hook switch.
With the handset lifted, a normal call can be made to the master porter's
exchange. During call reception and communication processes, it allows
lock release activation.
T
erminal connector description.
Positive, ground.
audio and digital communication.
uxiliary call repeater output.
a
+ , :
A/D :
SA :
–
A/D SA
+
_
107
MONITORS PROGRAMMING
Turn off the monitor to be programmed by holding presse
the door release push button for one second.
Once off, press the autoswitch-on push button.
d
While holding pressed the autoswitch-on push button,
simultaneously press the door release push button.
To show that the system is ready for programming, the door
panel will emit a tone and the image will appear on the
monitor. The push buttons can now be released. Lift the
handset off the monitor.
Press the door panel push button that will
call to this monitor. At this moment
both door panel and handset will
emit tones.
Each apartment must have one master unit only; in case of parallel units configure them
as slaves, whether they are monitors or telephones.
Make a call to check that the monitor has been successfully programmed.
Repeat these steps to program the rest of monitors.
Once the programming has been finished, set to OFF the programming
switch. If you don't, the door panel will reproduce a sound to advise that
the system is still into programming mode.
P
rogramming the Tekna R5 monitors.
With the handset lifted:
If programming the monitor as master, replace the
handset.
If programming it as slave, press the door release
push button, then replace the handset.
Master
Slave
IMPORTANT:
If the installation has a CD-PLUS/R5 converter with coded door panel or porter's exchange, the
programming codes assigned to the monitors must be between 1 and 250. To make it easier for
the user to make a call, can assign in a parallel manner another code in a 2 assignment chart
(see manual: T-590ML
or T-3403ML
).
nd
porter's exchange
coded door panel
Locate the configuration dip switch placed
EL631/R5 and set number 2 to ON, as described on page 99.
The door panel will emit a tone which indicates that it's in programming mode.
In systems with more than one door panel, the programming process shall be
done on the master door panel only.
at the upper right side of the back of
the module