XVI. Error code table
ERROR
WHAT HAPPENED
WHAT TO DO
Err 10
The water reaches the max level but does not
reach the min level in two minutes.
Error message can be cancelled by pressing
„ESC“
button. Combi oven can
be used in
„Hot air“
only. Please call your service company.
Err 11
Preheating of a boiler took longer then 6 min.
Error message can be cancelled by pressing
„ESC“
button. Combi oven can
be used in
„Hot air“
only. Please call your service company.
Err 12
When filling the boiler, the max water level is
not reached in 2 minutes.
Error message can be cancelled by pressing
„ESC“
button. Combi oven can
be used in
„Hot air“
only. Please call your service company.
Err 13
When filling the boiler, the min water level is
not reached in 2 minutes.
Check water supply line (open valve)
Error message can be cancelled by pressing „
ESC“
button. Combi oven can
be used in
„Hot air“
only. Please call your service company.
Err 14
One phase of a power distribution is missing Please call your service company.
Err 15
F2 motor thermal overload protection failure.
Indication of motor overheating above a set
limit.
Please call your service company.
Err 16
Preheating of a boiler took longer then 7 min.
Error message can be cancelled by pressing
„ESC“
button. Combi oven can
be used in
„Hot air“
only. Please call your service company.
Err 17
When emptying the boiler, the water level did
not decrease under the min level in 2min.
Error message can be cancelled by pressing
„ESC“
button. Combi oven can
be used in
„Hot air“
only. Please call your service company.
Err 18
When emptying the boiler, the water level did
not decrease under the max level in 2min.
Check the drain.
Error message can be cancelled by pressing
„ESC“
button. Combi oven can
be used in
„Hot air“
only. Please call your service company.
Err 26
Flap valve motor is not blocked or switch is
still closed.
Error message can be cancelled by pressing
„ESC“
button. Combi oven can
be used without
„Flap valve“
function.
Err 27
Flap valve motor is not blocked or switch
is still opened.
Error message can be cancelled by pressing
„ESC“
button. Combi
oven can be used without
„Flap valve“
function.
42
OPERATION MANUAL FOR GOLDSTEIN VISION COOKING CENTRES
Содержание Vision
Страница 1: ......