- Chapter 11 - Troubleshooting
Windrow 2500L Operator’s Manual MY18 - REV 1
PROBLEM
COMMON CAUSES
COMMON SOLUTION
Chem probe is not working
or is working too slow
Air leak in the vacuum
system
Check all hose clamps and fittings are tight
Lack of pressure to venturi in
top of tank
Check there are no kinked hoses and the
water pressure is about 100 PSI
Spray Nozzles
PROBLEM
COMMON CAUSES
COMMON SOLUTION
Streaky pattern coming from
nozzle
Nozzle tip blockages.
Check for blockages by removing the
nozzle, rinsing thoroughly with water and
cleaning with compressed air.
DO NOT clean by blowing into nozzle
with mouth.
Nozzle worn or damaged.
Visually inspect nozzle for damage or wear,
conduct a jug test if necessary.
No spray coming from nozzle
Nozzle tip blockages.
Check for blockages by removing the
nozzle, rinsing thoroughly with water and
cleaning with compressed air.
Check valve blockages.
Remove the check valve and clean as
required.
Chemical Probe
ISOLATING POSSIBLE AIR LEAKS
Step 1:
Check the operation of the chemical probe.
If this will transfer water at a minimum of 30 L/min
then this part of the system is okay.
If not check for air leaks at:
• Cam lever fitting at the probe
• Hose fittings
• Venturi – the venturi can suck air (less vacuum)
where the black drop-pipe connects to the
orange venturi
• The venturi may also suck air where the ‘lay flat’
hose joins the bottom of the black PVC drop
pipe
Step 2:
If probe works correctly but envirodrum will
not operate, check for air leaks in envirodrum fitting
(this must be thoroughly cleaned after each use) and
check interior pipes in the envirodrum for air leaks
or damage.
SUMMARY
Check the flow of water into venturi.
Then:
1. Check the probe only.
2. Check probe and envirodrum section.
NOTE:
Tests must be done with water because
the speed of the transfer is affected by chemical
viscosities.
Содержание Windrow MY18 2500L
Страница 4: ......
Страница 6: ...Auto Rate Control Raven SCS 450 61 Auto Rate Control Spray Application 62 Engine 63 ...
Страница 8: ...Windrow 2500L Operator s Manual MY18 REV 1 2 Chapter 1 Introduction ...
Страница 18: ...12 Chapter 4 5 N A Windrow 2500L Operator s Manual MY18 REV 1 ...
Страница 26: ...20 Chapter 6 Calibration Windrow 2500L Operator s Manual MY18 REV 1 ...
Страница 31: ...Chapter 7 Pre Operation 25 Windrow 2500L Operator s Manual MY18 REV 1 Wiring Schematic Raven SCS450 ...
Страница 32: ...26 Chapter 7 Pre Operation Windrow 2500L Operator s Manual MY18 REV 1 Wiring Schematic Manual Rate Control ...
Страница 48: ...42 Chapter 9 Booms Windrow 2500L Operator s Manual MY18 REV 1 ...
Страница 56: ...50 Chapter 10 Lubrication Maintenance Windrow 2500L Operator s Manual MY18 REV 1 ...
Страница 73: ...Chapter 12 Optional Accessories 67 Windrow 2500L Operator s Manual MY18 REV 1 ...
Страница 74: ...www goldacres com au ...