Chapter 8 - Operation -
35
Windrow 2500L Operator’s Manual MY18 - REV 1
The following information is provided as a general
guide for flushing your sprayer following a spray
application.
For more specific information regarding flushing, and
decontamination, specific to the products that you
are applying, it is recommended that you consult the
chemical label or your chemical supplier.
To use the flush water tank to flush pump & boom
only:
1. Turn pump off.
2. Turn 3 way ball valve to draw from flush water
tank rather than main product tank.
3. Set Raven console into manual mode.
4. Switch all boom sections to ON.
5. Hold increase button for 15-20 secs. This will
ensure that fast close valve is fully open to direct
all flow to booms (This will eliminate bypass from
the booms to main tank).
6. Turn pump ON. The pump will now draw water
from the flush water tank and direct all flow to
the booms.
7. Keep boom switches on until the contents of the
flush water tank has been run through the booms.
NOTE:
If the pressure gauge increases dramatically,
slow down pump RPM.
To flush entire system (pump, boom & tank):
1. Drain the main tank.
2. Connect to external water source (to provide
fresh water supply).
3. Turn main tank fill tap OFF to direct external
water supply to the fill manifold under pressure.
4. Engage tank rinse nozzles with the lever on EZ
control and allow rinsate to drain out through the
main tank drain.
5. Close main tank drain.
6. Add a quantity of fresh water (a minimum of
approximately twice the pumps capacity) to the
main tank (as per instructions under filling).
7. Turn on pump with agitator and bypass open to
allow fresh water to circulate.
8. Turn off all taps to allow the pressure relief valve
to blow off and purge the “relief to tank” line.
9. Operate induction equipment (if fitted), with a
quantity of fresh water in order to flush venturi
system.
10. Once complete drain chemical induction hopper
delivery hose externally.
11. Now follow the instructions for boom flushing as
above - keep ball valve drawing from main tank.
Flushing
There are 2 in-line pressure filters in the spray
pressure line that traps the minute particles that are
not collected by the main suction filters.
WARNING:
Always wear the recommended
personal protective equipment and use caution
while working with chemicals.
Unscrew the filter body. It may be necessary to use
the pressure filter tool (GA4522610). Allow the
chemical in the filter to dribble out into a suitable
container to avoid environmental contamination and
avoid personal contact. Clean or replace the filter
screen with the same mesh size as necessary and
then refit the filter body.
Pressure Filter Cleaning
Above:
Dual in-line pressure filters located on left
hand side chassis rail next to the induction hopper
mount.
Filter body
Содержание Windrow MY18 2500L
Страница 4: ......
Страница 6: ...Auto Rate Control Raven SCS 450 61 Auto Rate Control Spray Application 62 Engine 63 ...
Страница 8: ...Windrow 2500L Operator s Manual MY18 REV 1 2 Chapter 1 Introduction ...
Страница 18: ...12 Chapter 4 5 N A Windrow 2500L Operator s Manual MY18 REV 1 ...
Страница 26: ...20 Chapter 6 Calibration Windrow 2500L Operator s Manual MY18 REV 1 ...
Страница 31: ...Chapter 7 Pre Operation 25 Windrow 2500L Operator s Manual MY18 REV 1 Wiring Schematic Raven SCS450 ...
Страница 32: ...26 Chapter 7 Pre Operation Windrow 2500L Operator s Manual MY18 REV 1 Wiring Schematic Manual Rate Control ...
Страница 48: ...42 Chapter 9 Booms Windrow 2500L Operator s Manual MY18 REV 1 ...
Страница 56: ...50 Chapter 10 Lubrication Maintenance Windrow 2500L Operator s Manual MY18 REV 1 ...
Страница 73: ...Chapter 12 Optional Accessories 67 Windrow 2500L Operator s Manual MY18 REV 1 ...
Страница 74: ...www goldacres com au ...