Foreword: 

 

 

-

 

You have purchased a Petit Cube wood burner and we thank you for your custom. 

-

 

This burner has been carefully studied, designed and manufactured in France to provide 
complete satisfaction. 

-

 

It is essential to read this manual carefully before installing your burner. 

-

 

We recommend keeping this manual in a safe place, even once your burner has been installed

These appliances are tested to the criteria of the NF EN 13240 European standard.

 

TECHNICAL SPECIFICATIONS 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

* with a load of 1.68 kg of wood at 13.8% moisture 
content and a calorific power of 14.958 MJ/Kg.  
 
 
 
 
 
 

Firebox (L x H x D in cm). 

40 x 20 x 22 

Flue diameter 

Ø125 mm exterior 

Flue on the top or behind 

yes 

Recommended fuel 

Logs 

Front loader, maximum log size (in cm) 

33 cm 

Wide panoramic window (withstands up to 750°C) 

yes 

Cast iron firebox 

yes 

Controls 

manual 

Weight (kg) 

92 kg 

Power (kW) 

5 kW 

Corrected heated volume up to (m3) 

75 to 180 m

3

 

Fire duration at normal settings* 

45 mins. 

Smoke mass flow 

7.4 g/sec 

Output 

75.3 % 

CO level in smoke at 13% 0

2

 

0.07 % 

C0

2

 level in smoke 

8.34 % 

Concentration of discharged dust at 13% 0

2

 

38.3 mg/Nm

3

 

Consumption at normal setting 

2.24 kg/h  

Average smoke temperature 

292.1 °C 

Minimum distance to adjacent flammable materials 

45 cm / behind          
50 cm / sides      150 
cm / front 

Appliance for occasional use 

yes 

G

ro

u

n

d

/t

o

p

 o

fl

u

G

ro

u

n

d

/t

o

p

 o

fl

u

Содержание 388134

Страница 1: ...Wood burners Petit Cube ref 388134 Documentation provided for the user and installer Manual ref 4596 16 Version A Date 01 09 2016...

Страница 2: ...wer of 14 958 MJ Kg Firebox L x H x D in cm 40 x 20 x 22 Flue diameter 125 mm exterior Flue on the top or behind yes Recommended fuel Logs Front loader maximum log size in cm 33 cm Wide panoramic wind...

Страница 3: ...coal approved product All lining must be compliant with DTU 24 1 in France Its sizing follows precise calculation rules EN 13384 1 standard that only a professional is trained to define Remove chimne...

Страница 4: ...appliance is not designed to be used with the door open All the appliance s surfaces are active hot It is essential to take all precautions to avoid burns Take all precautions to keep children and th...

Страница 5: ...ad the fire when it is sufficiently low Do not open the door if you can see high flames as these risk to be taken in a back draft when the door is opened Always open the door gently to allow the draft...

Страница 6: ...e sure you remove all traces of oxidation using fine grain sandpaper Full cast iron wood burners with an enamel exterior finish require the inside of the firebox to be maintained This operation is all...

Страница 7: ...388134 Petit Cube Page 7 FITTING THE DEFLECTOR The deflector is fitted at the bottom on the back rib and at the top on the secondary air flue as shown below cross section view Deflector...

Страница 8: ...388112 053 27 4 Leg 1 2208 388116 053 9 1 Secondary air flue 1 4112 388112 053 28 4 Window holder 1 2071 660101 018 10 1 Back 1 2401 388112 053 29 1 H M6 nut 00001300265 11 1 Top 1 1101 388112 053 30...

Страница 9: ...388134 Petit Cube Page 9...

Страница 10: ...elements cannot be replaced under the warranty The same applies to the seals which are considered to be wear parts and are outside the scope of the warranty The warranty will not be applicable if The...

Отзывы: