Exploded view and parts list for wood burner 388134 Petit Cube: 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

N° 

Nb 

Description 

Coding 

 

N° 

Nb 

Description 

Coding 

Badge 

1 8501 034400 - 021 

 

20 

Ash-box 

1 3316 388112 096 

Ext. 

 Ø

125 nozzle 

1 4312 3721 - 53 

 

21 

Air shut-off control 

1 4196 388112 - 000 

Cleaning hatch (125) 

1 4230 3721 - 53 

 

22 

Protective plate 

1 2420 388112 - 000 

Ext. 

Ø

100 nozzle 

1 4312 388103 - 053 

 

23 

Air regulation control 

1 4120 388112 - 000 

Supply tube 

1 3509 388112 - 000 

 

24 

Damper seat 

1 4128 388112 - 000 

Air supply box 

1 5079 388112 - 053 

 

25 

Handle 

1 2878 388112 098 

Fire-dog 

1 0306 388112 - 053 

 

26 

Side 

1 2317 388116 - 053 

Damper 

1 4166 388112 - 053 

 

27 

Leg 

1 2208 388116 - 053 

Secondary air flue 

1 4112 388112 - 053 

 

28 

Window holder 

1 2071 660101 - 018 

10 

Back 

1 2401 388112 - 053 

 

29 

H M6 nut 

00001300265 

11 

Top 

1 1101 388112 - 053 

 

30 

6x40 grooved pin 

00001305127 

12 

Deflector 

1 0131 388112 - 053 

 

31 

Spring 961 

00001301991 

13 

Front 

1 2101 388112 - 053 

 

32 

JZC6 14x6x1 washer 

00001300900 

14 

Right side grate 

1 0262 388112 - 053 

 

33 

Braid diam 10.5 len1700 

00001304691 

15 

Left side grate 

1 0261 388112 - 053 

 

34 

Self adhesive braid diam 7 len 1250 

00001304860 

16 

Loader door 

1 2831 388112 - 053 

 

35 

Screw cylinder d30 M10 len30 

00001306750 

17 

Base 

1 2215 388112 - 053 

 

36 

EP4  Glass 313x333 

00001307902 

18 

Air regulation control yoke 

1 4125 388112 - 000 

 

37 

HC M5x8 cone-point screw 

00001306744 

19 

Air regulation control face 

1 4122 388112 - 000 

 

38 

TH M6x20 screw 

00001301240 

Содержание 388134

Страница 1: ...Wood burners Petit Cube ref 388134 Documentation provided for the user and installer Manual ref 4596 16 Version A Date 01 09 2016...

Страница 2: ...wer of 14 958 MJ Kg Firebox L x H x D in cm 40 x 20 x 22 Flue diameter 125 mm exterior Flue on the top or behind yes Recommended fuel Logs Front loader maximum log size in cm 33 cm Wide panoramic wind...

Страница 3: ...coal approved product All lining must be compliant with DTU 24 1 in France Its sizing follows precise calculation rules EN 13384 1 standard that only a professional is trained to define Remove chimne...

Страница 4: ...appliance is not designed to be used with the door open All the appliance s surfaces are active hot It is essential to take all precautions to avoid burns Take all precautions to keep children and th...

Страница 5: ...ad the fire when it is sufficiently low Do not open the door if you can see high flames as these risk to be taken in a back draft when the door is opened Always open the door gently to allow the draft...

Страница 6: ...e sure you remove all traces of oxidation using fine grain sandpaper Full cast iron wood burners with an enamel exterior finish require the inside of the firebox to be maintained This operation is all...

Страница 7: ...388134 Petit Cube Page 7 FITTING THE DEFLECTOR The deflector is fitted at the bottom on the back rib and at the top on the secondary air flue as shown below cross section view Deflector...

Страница 8: ...388112 053 27 4 Leg 1 2208 388116 053 9 1 Secondary air flue 1 4112 388112 053 28 4 Window holder 1 2071 660101 018 10 1 Back 1 2401 388112 053 29 1 H M6 nut 00001300265 11 1 Top 1 1101 388112 053 30...