Godin 388134 Скачать руководство пользователя страница 5

388134 Petit Cube

 

Page 5 

 

NOTE: 

 

When the appliance is running, move all materials that could be altered by heat away from it, such as furniture, paper, clothing. 

 

The control has two markings (+ and -). The more the control points towards the +, the higher the air intake capacity. Normal burning can 
be achieved using a position such as the above. 

 

CAUTION: 

 

We burning normally, the handle should not be touched with bare hands. Use the glove for the operation. Furthermore, the combustion 
chamber and the ash-box compartment must remain closed to prevent smoke from blowing back, except when the fire is being lit, or when 
it is being reloaded or when residue is being cleared out. 

 

Always keep the door closed when in use. 

 

Loading is via the door on the front of the appliance. 

 

At a normal rate, use 6 to 8 six cm diameter logs on a significant bed of embers, and set to positions 2 or 3.  

 

For heating over an extended period, only use 3 logs, but of a bigger diameter, 13 to 15cm on an average  bed of embers. 

For slow burning, leave the fire until the bed of embers has fallen correctly, then load 1 or 2 large logs, leave the big logs and set the air controls 
to the minimum.  

 

NOTE: The duration of the slow burn will depend on the wood used and the chimney’s stack effect. Do not load more than a 25 cm height of 
fuel. 

 

CONTROLLING THE APPLIANCE 

 

 

Allows follow the instructions. 

 

When lighting the fire for the first few times, only load limited amounts to check that the unit is in working order. Gradually increase the 
wood load over several days. 

 

Do not use the appliance as an incinerator. 

 

Only use the recommended fuel. 

 

Do not light the fire if the window is broken or cracked. Have it replaced before any further use. We recommend you contact your dealer 
to have the window replaced as a paying service. We insist on the need to replace the door and window seals at the same time, and above 
all not to tighten too much when reassembling, so that dilation is not hampered. 

 

After  a  long  period  of  inactivity,  check  that  the  flue  is  not  obstructed,  as  well  as  the  connecting  pipe  and  the  smoke  flues  inside  the 
appliance. 

 

Loading: VERY IMPORTANT RECOMMENDATION 
Only load the fire when it is sufficiently low. Do not open the door if you can see high flames, as these risk to be taken in a back draft when 
the door is opened. 
Always open the door gently to allow the draft to set itself up and thus avoid any back blow from the chimney. 

 

IMPORTANCE OF THE FUEL 

 

This appliance should give full satisfaction. Remember that any appliance can only release the energy contained in the fuel it burns. 
 
If you believe your appliance is not heating enough, one can assume that: 

 

Either the quantity of fuel being burnt is insufficient. 

 

Or the burned fuel does not have sufficient available energy. 

Only burn dry wood that was felled more than two years before its use (36 months would be even better). We strongly recommend the use of 
NF label heating firewood. 

 

As a rule, all wood has the same calorific power for the same weight. Hard wood will be interesting because it is denser and often less humid. 
The moisture contained in the wood varies by 15% for dry wood, to 50% for damp wood. Remember that a lot of energy will be required to 
evaporate that water. 
The energy available for heating would be 4.16 Wh per Kilogram of dry wood. For wood with 50% moisture content, it would only be 1.73 
Wh. 

 

Furthermore, the use of damp wood would cause condensation in the chimney, rapidly dirtying it and would risk, in the long term, causing 
chimney fires. 

 

ASH REMOVAL 

 

 

Empty the ash box at least every 2 to 3 days depending on use. Precautions must be taken when doing this. Make sure to use the glove to 
carry the ash-box and the hook to manipulate it. 

 

Never let ash accumulate in the ash-box until it is in contact with the grate. This would prevent it from cooling and would cause damage 
to it very quickly. 

 

CHIMNEY CLEANING 

 

 

Have your chimney swept by a professional using a mechanical tool at least twice per year, including once during the heating season. The 
contractor must issue you with a certificate. The flues can also be maintained using a suitable product. This, however, cannot replace the 
mechanical sweeping of the chimney. 

 

Check the appliance and make sure the door seals are in good condition. Replace them if necessary. 

 

Completely clean the inside of the appliance including the smoke flues. 

 

Clean the window using GODIN NET window special (ref. 0009). 

 

If a chimney fire starts, close the air intakes and call the fire brigade. 

 
 
 
 

Содержание 388134

Страница 1: ...Wood burners Petit Cube ref 388134 Documentation provided for the user and installer Manual ref 4596 16 Version A Date 01 09 2016...

Страница 2: ...wer of 14 958 MJ Kg Firebox L x H x D in cm 40 x 20 x 22 Flue diameter 125 mm exterior Flue on the top or behind yes Recommended fuel Logs Front loader maximum log size in cm 33 cm Wide panoramic wind...

Страница 3: ...coal approved product All lining must be compliant with DTU 24 1 in France Its sizing follows precise calculation rules EN 13384 1 standard that only a professional is trained to define Remove chimne...

Страница 4: ...appliance is not designed to be used with the door open All the appliance s surfaces are active hot It is essential to take all precautions to avoid burns Take all precautions to keep children and th...

Страница 5: ...ad the fire when it is sufficiently low Do not open the door if you can see high flames as these risk to be taken in a back draft when the door is opened Always open the door gently to allow the draft...

Страница 6: ...e sure you remove all traces of oxidation using fine grain sandpaper Full cast iron wood burners with an enamel exterior finish require the inside of the firebox to be maintained This operation is all...

Страница 7: ...388134 Petit Cube Page 7 FITTING THE DEFLECTOR The deflector is fitted at the bottom on the back rib and at the top on the secondary air flue as shown below cross section view Deflector...

Страница 8: ...388112 053 27 4 Leg 1 2208 388116 053 9 1 Secondary air flue 1 4112 388112 053 28 4 Window holder 1 2071 660101 018 10 1 Back 1 2401 388112 053 29 1 H M6 nut 00001300265 11 1 Top 1 1101 388112 053 30...

Страница 9: ...388134 Petit Cube Page 9...

Страница 10: ...elements cannot be replaced under the warranty The same applies to the seals which are considered to be wear parts and are outside the scope of the warranty The warranty will not be applicable if The...

Отзывы: