388134 Petit Cube
Page 4
CONNECTION TO THE CHIMNEY FLUE
The appliance should be connected in compliance with DTU 24.1 (in France). The safety distances from the outer walls of the connecting flue
and the chimney flue from any flammable material (A) must also be compliant with the requirements of this standard. They especially depend
on the type of flue, its thermal resistance and its temperature class. There should be no junctions within the thickness of the floor (plan offset
B).
Example of a connection to the chimney flue
General connection rules for a pipe on the top or at
the back (if possible)
USER INSTRUCTIONS
•
Before using the appliance, read the instructions and recommendations carefully.
•
The appliance must be installed in accordance with applicable national regulations in the country the appliance is installed.
•
Installation by a professional is strongly recommended.
•
Never obstruct the provided air intakes.
•
The appliance must be connected to a chimney flue that is not connected to other appliances. It is not suitable for use on multiple flues.
•
Never make any unauthorised alterations to the appliance.
•
The appliance is not designed to be used with the door open.
•
All the appliance’s surfaces are active (hot). It is essential to take all precautions to avoid burns.
•
Take all precautions to keep children and the elderly at a sufficient distance to prevent accidents.
AIR SUPPLY
•
The appliance takes the air it needs from the room it is in. Therefore always make sure it has a sufficient air supply.
•
Part of this air is used as “primary air”, while another part is transported to the front to be used as “secondary air” to complete combustion
and limit dirt accumulating on the window.
•
The quantity of air used for combustion must be compensated for by an external air supply (plan for a ventilation grate).
LIGHTING AND ADJUSTING
•
Open the door.
•
Put the usual lighting materials inside, light and load moderately while leaving the air intake fully open.
•
To encourage the fire to light, the door can be left slightly ajar for a few minutes on condition that it is watched over continuously.
•
Once the fire has started burning correctly, load the required quantity and adjust the combustion using the air regulation controls.
Chimney flue
Inspection hatch
Non flammable material
ceiling
masonry
Protective metal plate
Connecting diameter
Inspection hatch
Connecting diameter
Chimney flue
Non flammable material
masonry
Protective metal plate