GMG VM26-J Скачать руководство пользователя страница 8

Page 6

1OPVM26EN – April 2018

VM26-J

 Safety

Additional Safety Hazards

Explosion and Fire Hazards

DO NOT operate the machine in hazardous locations or locations where potentially 
flammable or explosive gases or particles may be present.

Damaged Machine Hazards

Conduct a thorough prestart inspection of the machine and test all functions before each work 
shift to check for damage, malfunction and unauthorized modification. Tag and remove a 
damaged, malfunctioning or modified machine from service. DO NOT use a damaged, 
malfunctioning or modified machine.

Routine maintenance must be performed by the operator before each work shift. Scheduled 
maintenance must be performed by a qualified service technician at scheduled intervals. Tag 
and remove from service any machine that has not had scheduled preventative maintenance 
performed.

Check that all safety and instructional decals are in place and undamaged. 

Check that the operator’s, safety and responsibilities manuals are present in the storage 
container located in the platform. All manuals must be complete, undamaged and readable.

Bodily Injury Hazards

DO NOT operate the machine when there is a hydraulic fluid or air leak. Hydraulic fluid or air 
under pressure can penetrate and/or burn skin.

All compartments must remain closed and secure during machine operation. Improper 
contact with components under any cover will cause serious injury. Only trained maintenance 
personnel should access compartments. The operator should only access a compartment when 
performing prestart inspection.

Weld Line to Platform Safety (if equipped)

Read, understand and follow all warnings and instructions provided with the welding power 
unit.

Do not connect weld leads or cables unless the welding power unit is turned off at the platform 
controls.

DO NOT operate unless the weld cables are properly connected.

DO NOT connect the ground lead to the platform.

Battery Safety

Burn Hazards

Batteries contain acid. Always wear protective clothing and eye wear when working with 
batteries.

Avoid spilling or contacting battery acid. Neutralize battery acid spills with baking soda and 
water.

Explosion Hazard

Keep sparks, flame and lighted tobacco away from batteries. Batteries emit explosive gas. 
Leave the battery tray open while charging to avoid gas buildup.

Electrocution Hazard

Avoid contact with electrical terminals.

Содержание VM26-J

Страница 1: ...t Locations 7 Platform Controls 8 Lower Controls 9 Workplace Inspection 10 Operating Instructions Function Tests 11 Prestart 11 Functions Test 11 Operating Instructions 16 Shutdown Procedure 19 Batter...

Страница 2: ...ength 33 5 85 m Platform width 35 8 91 m Toeboard height 6 7 0 17 m Height stowed B 78 1 99 m C Length stowed 108 6 2 76 m Width D 39 99 m Wheelbase E 47 1 2 m F Ground clearance center pothole bars g...

Страница 3: ...he operator of the aerial work platform is not alone on the workplace during operation Modifications of this machine from the original design and specifications without written permission fromGMGarest...

Страница 4: ...s The ANSI SIA A92 5 2006 Manual of Responsibilities is considered a part of this machine and can be found in the manual compartment located at the platform control station To ensure safe use of machi...

Страница 5: ...ricallineorapparatuscarryingover300Voltsupto50 000 Volts Onefoot 30 5cm additional clearance is required for every additional 30 000 Volts Observe Minimum Safe Approach Distance This machine is not el...

Страница 6: ...5 m s If wind speeds exceed 28 m p h 12 5 m s when the platform is elevated carefully lower the platform and discontinue operation DO NOT increase the surface area of the platform i e cover the rails...

Страница 7: ...tform rail before moving Be aware of limited sight distance and blind spots when driving or operating Be aware of extended platform position s when moving the machine Reduce travel speed when moving t...

Страница 8: ...readable Bodily Injury Hazards DO NOT operate the machine when there is a hydraulic fluid or air leak Hydraulic fluid or air under pressure can penetrate and or burn skin All compartments must remain...

Страница 9: ...nts Component Locations 13355 Guardrails Entry Gate Entry Gate Lift Mast Rotating Turret Tie Down Lift Points Tie Down Lift Points Platform Controls Platform Controls Manuals Case Foot Interlock Switc...

Страница 10: ...the Foot Interlock Switch then use the Left Control Paddle to rotate the turret 5 Jib Function Select Press this switch to enable the Jib function Depress the Foot Interlock Switch then use the Right...

Страница 11: ...latform 5 Power On Indicator Light ON indicates machine is ready for use Light OFF may indicate a depressed Emergency Stop Button Key Switch in the OFF position or discharged batteries 6 Base Control...

Страница 12: ...t is the correct machine for the job Be aware of workplace conditions and continue to watch for hazards while operating the machine Workplace Inspection Before operating the machine check the workplac...

Страница 13: ...w operators must perform a Pre Start Inspection and Functions Test prior to operating the machine Operators must comply with all employer and job site rules and governmental regulations regarding the...

Страница 14: ...n enable switch then push the Base Control Paddle up Result The platform should raise 11 Push and hold the Lift Function enable switch then push the Base Control Paddle down Result The platform should...

Страница 15: ...rol Paddle up Result The jib and platform should rise 21 Push and hold the Jib Function enable switch then push the Base Control Paddle down Result The jib and platform should lower Test the Emergency...

Страница 16: ...34 Press and hold the Foot Interlock Switch on the platform floor Slowly push the Right Control Paddle rearward Result The platform should lower The descent alarm should sound while the platform is lo...

Страница 17: ...he machine begins to move then return the handle to the center position Result The machine should move in the direction that the yellow up arrow points on the control panel then come to an abrupt stop...

Страница 18: ...ils while the platform is elevated use the Emergency Lowering Valve to safely lower the platform DO NOT climb down the mast or exit the platform The Emergency Lowering Valve is used to lower the platf...

Страница 19: ...ols 3 Be sure the battery pack is connected before operating the machine To Position Platform 1 Press the Lift Rotate or Jib Function Select switch as desired 2 Press and hold the Foot Interlock Switc...

Страница 20: ...ease speed Slowly move the Right Control Paddle toward center Stop Return the Right Control Paddle to center or release the Foot Interlock Switch Use the color coded direction arrows on the platform c...

Страница 21: ...downhill end lay the level on the top edge of the piece of wood and lift the end until the piece of wood is level While holding the piece of wood level measure the distance from the bottom of the piec...

Страница 22: ...let Do not use an external charger or booster battery Charge the battery in a well ventilated area Use proper AC input voltage for charging as indicated on the machine Use only GMG authorized batterie...

Страница 23: ...fluid under pressure can penetrate and burn skin damage eyes and may cause serious injury blindness and death Repair leaks immediately Fluid leaks under pressure may not always be visible Check for pi...

Страница 24: ...ntified in the Pre Start Inspection Checklist on page 24 Frequent and Annual Maintenance Frequent Inspection Checklists and Annual Inspection Reports must be completed by qualified service technicians...

Страница 25: ...vel daily Scheduled Maintenance Change yearly or every 600 hours whichever occurs first Do not substitute other fluids as pump damage may result Fill to the middle of the dipstick with platform in the...

Страница 26: ...yte levels Hydraulic hoses fittings cylinders and manifolds Drive motors Slide blocks wear pads Tires and wheels Ground strap Limit switches alarm and beacon Nuts bolts and other fasteners Platform en...

Страница 27: ...escription Perform all checks listed on Pre Start Inspection Inspect the condition of hydraulic fluid in the reservoir Oil should be a clear and amber in color Batteries check specific gravity clean e...

Страница 28: ...il it has been checked by a trained qualified mechanic Machine functions will not operate Battery properly connected Battery fully charged Key Switch in proper position Both Emergency Stop Switches re...

Страница 29: ...of sufficient capacity to withstand the machine weight See the serial plate for the machine weight Fully lower the platform Be sure the deck extension is retracted and the controls and component tray...

Страница 30: ...the Platform Emergency Stop Switch Test platform control functions Select slow drive speed mode Carefully drive the machine off the transport vehicle with the winch attached Note The brakes are autom...

Страница 31: ...1OPVM26EN April 2018 Page 29 VM26 J Transport and Lifting Instructions NOTES...

Страница 32: ...Global Machinery Group Inc 3428 Bullock Lane San Luis Obispo CA 93401 USA Phone 1 805 303 2066 Toll Free USA Canada 800 303 0499 www goGMG com Global Machinery Group Inc...