1OPVM26EN – April 2018
Page 11
VM26-J
Operating Instructions & Function Tests
Operating Instructions & Function Tests
DO NOT operate this machine until you have read and understood this manual, have performed the Workplace Inspection,
Prestart Inspection and Routine Maintenance, and have completed all the test operations detailed in the Operating Instructions
section.
This section provides instructions and tests for each function of machine operation. Follow all safety rules and instructions. The
operator must conduct inspections and a Functions Test of the machine before each work shift to check that all machine systems are
working properly.
Test the machine on a firm level surface with no debris, drop-offs, potholes or overhead obstructions. Perform each step outlined in
this section.
This machine shall only be operated by trained and authorized personnel. If multiple operators use this machine, all must be trained,
qualified and authorized to use it. New operators must perform a Pre-Start Inspection and Functions Test prior to operating the
machine.
Operators must comply with all employer and job site rules and governmental regulations regarding the use of personal protective
equipment.
DO NOT use a machine that is malfunctioning. If any function does not perform as described, tag the machine and remove for repair
by a qualified service technician. After repairs are completed, a Pre-Start Inspection and Functions Test must be performed before
using the machine.
Refer to
Platform Controls
on page 8 and
Lower Controls
on page 9 when performing the following functions tests and operating
instructions.
Prestart
• Perform
Prestart Inspection
(see
page 24).
• Check Emergency Stop Switch at the platform controls – pull to reset.
• Check Main Power/Lower Emergency Stop Switch at the lower controls – pull to reset.
Functions Test
1 Select a test area that is firm, level and free of obstruction.
2 Be sure the battery pack is connected.
At the Ground Controls
3 Set the red Emergency Stop button to the on position by pulling it out at both the
ground and platform controls.
4 Turn the Key Switch to ground control.
13358