LSX3100 User Manual, January 2017
© 2017 Global Payments Inc.
44
CONFIDENTIAL
Main Power Supply
Main Power Supply Problem
Diagnostics
No light on ON/OFF switch
1. Check AC input cable to power supply for
loose connection.
2. Check AC input cable connection to the wall
outlet or UPS.
No AC power to PC unit
1. Check AC OUT cord on top of power supply
for loose connection.
2. Check AC IN cord to back of PC for loose
connection.
3. Check power switch on both power supply
and PC unit.
No DC power to devices
Please call our 24/7 CAMS support desk (800-
500-1973).
Indicator Lights
Indicator Lights Problem
Diagnostics
No light
1. Check cable connection from SIC board to
flicker board.
2. Check to ensure the light signal on flicker
board is working.