Note Dispensing Unit Sensors
The following illustration shows the HCDU sensors:
Note Dispensing Unit Sensors
Cash Dispensing Unit (CDU) Error Codes and Diagnostics
Error Code
CDU Error Code Description and Diagnostics
C0000
Normal
C0011
CDU exit sensor (A) to cash tray blocked before dispensing
C0012
Reject gate timing sensor (E) blocked
1. Check the sensor RIGHT/LEFT for blockage.
2. Check to ensure the sensor is working properly.
3. Check cable from the sensor to MAIN B/D for damage or loose connector.
4. Measure sensor voltage:
Normal range of 50~250 mV at empty
Normal range of 2~5 V when blocked
5. Replace GATE sensor when the voltage is not in the normal range.
6. Replace Main B/D.
C0021
Double detection timing sensor (H) blocked
1. Check the sensor for blockage.
2. Check to ensure the sensor is working properly.
3. Check the cable from sensor to MAIN B/D for damage or loose connector.
4. Measure sensor voltage <transmitter normal range of 1~3V>.
Normal range of 50~250 mV at empty
Normal range of 2~5 V when blocked