Error Code
CDU Error Code Description and Diagnostics
1. Check cables from cassette exit to double timing sensor for damage or loose
connector.
2. Check belt for proper engagement.
3. Check cable from sensor to feed module B/D for damage or loose connector.
4. Measure sensor voltage <transmitter normal range of 1~3V>.
Normal range of 50~250 mV at empty
Normal range of 2~5 V when blocked
5. Replace Inlet sensor when the voltage is not in the normal range.
6. Replace Main B/D.
C0083
Reject gate timing sensor(E-LEFT), blocked during dispensing
1. Check sensor LEFT for blockage.
2. Check cable from sensor to main B/D for damage or loose connector.
3. Measure sensor voltage <transmitter normal range of 1~3V>.
Normal range of 50~250 mV at empty
Normal range of 2~5 V when blocked
4. Replace Gate sensor when the voltage is not in the normal range.
5. Replace Main B/D.
C0084
Reject gate timing sensor(E-RIGHT), blocked during dispensing
1. Check sensor RIGHT for blockage.
2. Check cable from sensor to main B/D for damage or loose connector.
3. Measure sensor voltage <transmitter normal range of 1~3V>.
Normal range of 50~250 mV at empty
Normal range of 2~5 V when blocked
4. Replace Gate sensor when the voltage is not in the normal range.
5. Replace Main B/D.
C0085
Note not arriving at reject gate timing sensor (E-LEFT)
1. Check note path for jam.
2. Check note for interference or blockage.
3. Check belt for proper engagement.
4. Replace CDU.
C0086
Note not arriving at count sensor (B) during dispensing
1. Check note path for jam.
2. Check belt for proper engagement.
3. Check note path structure for damage
4. Check reject gate for interference or damage.
5. Check belt and gear for proper engagement.
6. Measure sensor voltage <transmitter normal range of 1~3V>.
a. Normal range of 50~250 mV at empty.
b. Normal range of 2~5 V when blocked.
7. Replace sensor when the voltage is not in the normal range.
8. Replace Main B/D.