LSX3100 User Manual, January 2017
© 2017 Global Payments Inc.
36
CONFIDENTIAL
Error Code
CDU Error Code Description and Diagnostics
1. Check sensor cable for loose connector.
Receiver: YELLOW, BLACK cables
Transmitter: RED, BLUE cables
2. Replace double B/D.
3. Replace Main B/D.
C0045
Note miscount detected (#note requested < # note counted)
1. Measure sensor voltage <transmitter normal range of 1~3V>.
Normal range of 50~250 mV at empty
Normal range of 2~5 V when blocked
2. Replace sensor when the voltage is not in the normal range.
3. Replace Main B/D.
C0047
1st cassette failure to pick up
1. Check note inside cassette for interference by foreign object.
2. Check gears inside cassette for debris between gear teeth.
3. Check rollers inside cassette for damage.
4. Check push plate for interference.
5. Check cassette exit path for blockage.
6. Replace cassette.
C0049
Zero note requested
1. Perform CDU ROM Version Check.
1 CST CDUU11V normal
2 CST CDUU21V normal
3 CST CDUU31V normal
4 CST CDUU41V normal
2. Replace Main B/D.
C004A
CST exit sensors (I, J, K, L) timeout
1. Measure sensor voltage <transmitter normal range of 1~3V>.
Normal range of 50~250 mV at empty
Normal range of 2~5 V when blocked
2. Replace sensor when the voltage is not in the normal range.
3. Replace Main B/D.
C004D
1st cassette not detected
1. Check 1st CST for its home position.
2. Check cable from MAIN B/D to 1st CST for damage or loose connector.
3. Replace cassette.
4. Replace Main B/D.
C004E
2nd cassette not detected
1. Check 2nd CST for its home position.
2. Check cable from 2nd feed module B/D to 2nd CST for damage or loose
connector.
3. Check cable from 2nd feed module B/D to main B/D for damage or loose
connector.
4. Replace cassette.
5. Replace Main B/D.