         WARNING

  

 Keep  compressor  in  upright  position  for  24  hours 

before water connections and initial power-on. Failure 

to do so will void warranty.

•  For indoor commercial use only.

•   All installation work must be performed by authorized 

service personnel.

•   Two or more people are recommended to lift and install 

the unit.

•   To avoid the risk of property damage and/or personal 

injury, mount the unit to a flat finished wall surface with 

adequate support.

•   Check  local  codes  for  plumbing  requirements  prior 

 

to installation.

•   Prior  to  initial  installation,  install  a  shut-off  valve  (not 

included) from the water supply.

•   Thoroughly flush all water lines and fittings of all foreign 

matter before connecting to the cooler. Failure to do so 

will void warranty.

•   Check for any leaks before initial operation.

•   DO NOT attempt to repair or replace any part of your 

appliance  unless  it  is  specifically  recommended  in 

this manual. All other services should be referred to a 

qualified technician.

•  For use with clean, clear potable drinking water only.

•   Shut-off water supply during installation to reduce risk 

of water damage. 

•   Ensure  proper  ventilation  by  allowing  appropriate 

clearance of housing louvers to the wall on each side 

of the cooler, as specified in rough-in guide.

•   NEVER wire the compressor directly to an electrical supply.

•  DO NOT allow children to play with the appliance.

•   Interior of unit may contain sharp edges. Wear gloves 

when handling or servicing unit.

•  Failure to follow installation instructions will void warranty.

Note:  These fixtures are intended for indoor commercial 

use  only.  Do  not  expose  to  freezing  temperatures. 

The  grounding  of  electrical  equipment  to  water  lines  is 

a  common  procedure.  This  grounding  may  be  in  the 

building or occur away from the building. This grounding 

can  cause  electric  feedback  into  the  water  cooler 

creating an electrolysis which creates a metallic taste or 

causes the water metal content to increase. Connect to 

water supply using non-conductive materials.

Model 761219

b82045fc-0b136962-90871f19-f891407c

TM

TM

Read this manual thoroughly prior to 

installation, operation or maintenance. 

Keep these instructions in a safe location 

for future reference.  For questions, visit 

globalindustrial.com or contact Customer 

Service at 1-800-645-2982.

System 761219 certified by IAPMO 
R

&

T against to NSF/ANSI/CAN 372 

for lead free compliance

Содержание 761219

Страница 1: ...hnician For use with clean clear potable drinking water only Shut off water supply during installation to reduce risk of water damage Ensure proper ventilation by allowing appropriate clearance of hou...

Страница 2: ...ep these instructions in a safe location for future reference Keep compressor in upright position for 24 hours before water connections and initial power on Failure to do so will void warranty It is r...

Страница 3: ...3 User s Manual Wall Mounted Water Bottle Refilling Station Check local codes for plumbing requirements prior to installation b82045fc 0b136962 90871f19 f891407c 287mm 10 1 4 in...

Страница 4: ...cess Door Key WARNING Assembly and installation of equipment should be performed by 2 people 1 2 H2 H1 1 2 3 Remove Lower Cover Using the Anti Theft Screw Star Key remove the 4 screws at the bottom of...

Страница 5: ...right side up and carefully feed connections though the Stainless Steel Pan hole Ensure gasket is seated properly and lies flat Attach Bottle Filler Top Assembly to the Stainless Steel Pan using 2 H3...

Страница 6: ...s Connect white Activation Connector C to Power Supply C in the Cooling System Attach stainless steel pan Feed the Reset Button Connection through the Cooling System s frame and carefully lower the St...

Страница 7: ...e wall using appropriate anchors Hanging assembled unit to wall Carefully hang assembled bottle filler onto the wall by lowering onto both top and bottom wall mount brackets 8 9 Note To comply with AD...

Страница 8: ...d into place Turnbothwatercontrolvalvestotheopenposition Check all connections for leaks If leaks are detected ensure all connections are tight and are fully inserted 11 13 12 Closed Closed Closed Ope...

Страница 9: ...ards please read all instructions and warnings Installation service and maintenance should be All parties must follow proper safety procedures and precautions at all times Do Not Install Damaged Produ...

Страница 10: ...ial water flow may have sputter due to air in the water lines this will be eliminated once air is purged from all water lines To operate bottle filler verify proper dispensing by placing bottle hand o...

Страница 11: ...elect 3600 4 Tap ENTER button to confirm your filter size Resetting Bottle Counter 1 Press and hold ENTER button for 5 seconds 2 Tap ENTER button until Reset Ct is displayed on the LCD screen then tap...

Страница 12: ...When filter level is at 0 0 LED bars will be displayed LCD will display CHG FLT entire time Issue Possible Cause Suggested Action Water temperature not cool The thermostat is set too high Lower the w...

Отзывы: