Chapter One
www.glentek.com
6
MANUAL # 9675-1035-000-A
1.3 Mode of Operation
Changing the Mode of Operation dial (SW1) (see pg. 26) will modify the configuration of the spindle
drive. Aligning the dial to any of the positions listed below will alter the drive to those settings. If none
of the settings below match your preference please contact one of Glentek’s sales engineers for
assistance. The drive is shipped with the dial at position 0 (zero)
Mode of Operation Position Settings
Position
Power (HP)
RPM
Sensor/VFD
Part Number
Model Number
0
15
10K
Sensor
7700
SMB9675-1A-1-7700
1
15
7.5K
Sensor
7701
SMB9675-1A-1-7701
2
15
10K
VFD
7702
SMB9675-1A-1-7702
3
10
10K
Sensor
7703
SMB9675-1A-1-7703
4
10
7.5K
Sensor
7704
SMB9675-1A-1-7704
5
10
10K
VFD
7705
SMB9675-1A-1-7705
6
20
10K
Sensor
7707
SMB9675-1A-1-7707
7
20
7.5K
Sensor
7708
SMB9675-1A-1-7708
8
20
10K
VFD
7709
SMB9675-1A-1-7709
9
5
10K
Sensor
7710
SMB9675-1A-1-7710
A
5
7.5K
Sensor
7711
SMB9675-1A-1-7711
B
5
10K
VFD
7712
SMB9675-1A-1-7712
C
-
-
-
-
-
D
-
-
-
-
-
E
-
-
-
-
-
F
-
-
-
-
-
Note
: Positions C, D, E, and F are reserved for future configurations.
Note:
Align the dial to the desired configuration before installation or disable the drive with an M5
(spindle stop) command BEFORE rotating the dial. The four place seven-segment displays will
display the operation mode selected (i.e. 7700, 7701, etc.) for seven seconds, then reverts to
displaying motor rpm. Enable the drive to run in the new mode.
Содержание SMB9675-1A-1-7700
Страница 2: ...www glentek com 2 MANUAL 9675 1035 000 A...
Страница 25: ...www glentek com Drawings Diagrams MANUAL 9675 1035 000 A 25...
Страница 26: ...Drawings Diagrams www glentek com 26 MANUAL 9675 1035 000 A...
Страница 27: ...www glentek com Drawings Diagrams MANUAL 9675 1035 000 A 27 Vector Drive Connection Diagram Page 1...
Страница 28: ...Drawings Diagrams www glentek com 28 MANUAL 9675 1035 000 A Vector Drive Connection Diagram Page 2...
Страница 32: ...www glentek com 32 MANUAL 9675 1035 000 A...