Instruction Manual ZS100T, ZS150T & ZS200T Series II (MAM-870) Senator Industrial Air Compressors
17
b.
During operation, it is prohibited to loosen any pipes, bolts and screw-plugs in the unit.
And individual valves in the unit shouldn’t be opened or closed at random.
c.
Observe the oil level. If the oil level is too low or not visible, the compressor should
be shut down for oil refilling.
d.
The operators in each shift should complete the operation record including the discharge
pressure, system pressure, air discharge temperature, oil level, operation time, etc. If
possible, the infrared temperature detector can be applied to inspect the temperature at
individual points and the power supply voltage and current may also be recorded.
3.3 Long-Term Shutdown
3.3.1 Preparation
If long-term shutdown is required for the compressor, the following steps should be
performed:
a.
Any faults should be rectified in preparation for the unit’s future use.
b.
The water in the oil cooler should be completely drained out to prevent internal
corrosion.
c.
All openings should be enclosed with plastic cloth or oiled paper to prevent the ingress
of moisture and dust.
d.
If the unit is out of service for more than two months, it will be necessary to replace the
lubricating oil before that and to operate it for 30 minutes. After three days, the
condensate in the oil separation tank should be completely drained out.
3.3.2 Restarting
a.
Remove the protective plastic cloth or oiled paper.
b.
Measure the insulation resistance of motors to ground, which should be more than
1
MΩ.
c.
Follow the initial start-up procedure in Section 3.1 to restart the unit.
Содержание MAM-870
Страница 2: ......
Страница 8: ...Instruction Manual ZS100T ZS150T ZS200T Series II MAM 870 Senator Industrial Air Compressors 4...
Страница 39: ......
Страница 40: ......
Страница 41: ...INSTRUCTION MANUAL MAM 870 COMPRESSOR CONTROLLER...
Страница 42: ......
Страница 58: ...NOTES...
Страница 59: ......
Страница 60: ......