Instruction Manual M A M - 8 7 0
Senator Industrial Air Compressors
10
PARAMETER
SET VALUE
FUNCTION
FAN A
TARGET
CUR
000.0A
Enter the target current value when the
compressor is running; the controller
will divide the target current value by the
sample input current value to work out
the coefficient. The target value is for
calculation only; will not be saved.
COEF.
1.000
Controller displays the current value =
sample value × COEF.
FAN B
TARGET
CUR
000.0A
Enter the target current value when the
compressor is running; the controller
will divide the target current value by the
sample input current value to work out
the coefficient. The target value is for
calculation only; will not be saved.
COEF.
1.000
Controller displays the current value =
sample value × COEF.
FAN C
TARGET
CUR
000.0A
Enter the target current value when the
compressor is running; the controller
will divide the target current value by the
sample input current value to work out
the coefficient. The target value is for
calculation only; will not be saved.
COEF.
1.000
Controller displays the current value =
sample value × COEF.