8
GKD Technik Ltd
M3000007
Screen Layout con�nued...
1
2
3
4
5
6
ALO Symbol
3RCI+ SpaceGuard Systems that are certified to work Adjacent Line Open will
show the symbol “
ALO √
”, 3RCI+ systems that are not cer�fied to work Adjacent
Line Open, or approved systems without opera�onal slew limits or virtual walls,
will show “
ALO X
”.
In-gauge
Shows green when the machine is within gauge to travel. Will also show red
when a slew limit is exceeded or a height limit is exceeded.
Dig Mode
If the system is in dig mode this icon shows green and the motion cuts and
alarms on overload are disabled, the blue beacon is not illuminated.
Height
Height of li� point from ground level (road mode) or rail head (rail mode).
Active Li�
Point
The current ac�ve li� point is shown here. Possible options are
BP
(Bucket Pin),
ALP
(Auxiliary Li� Point),
QH
(Quick hitch), or
TLJ
(demountable Tele-jib).
If
nothing shown here then only one li�ing point is enable (Bucket Pin).
Radius
Radius of current li� point from the slew centre of the machine.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Load
Displays the current load on hook. This will include any attachments and the
quick hitch.
7
19