11
GKD Technik Ltd
M3000007
Opera�on
Switching On
The RCI automa�cally engages when the machine is
switched on and started. The system automa�cally
detects the machine status. During the start up
sequence the internal alarm will sound until the
system is fully opera�onal. The operator will then
be prompted to stop the alarm sounding.
At start up the system requires an eight digit driver
iden�fica�on code to be entered before the
machine is made ac�ve. The operator should enter
their PTS number. Where the operator has a 6 digit
Sen�nel card number, it is suggested that two zeros
are typed in first, followed by the 6 digit Sen�nel
number.
External Indicator Beacons
�
Blue Beacon
- The system is fitted with at least one blue beacon on the outside of the cab. This may
take the form of a lamp or LED strip. The beacon is illuminated when the machine is configured in a
li�ing duty. The beacon will be turned off when the machine is in DIG mode. When lifting in Tandem
Li� mode, the blue beacon will cycle on and off at 2 second intervals.
�
Orange Beacon
- 3RCI+ SpaceGuard systems will have an orange beacon installed on the roof of the
cab. This beacon illuminates when an angular slew limit or a virtual wall has been set AND the
foreman key switch on the display is in the locked posi�on.