GKD Technik Ltd
M3000007
Paired Machine in Mo�on Overload
This will be shown if the paired machine reaches its
Max Safe Working Load.
When this happens, all mo�ons on both machines
are cut and a similar message is shown to the other
Operator.
Pressing Accept will log that you have acknowledged
the overload, but the mo�on cuts will not be
released un�l the Operator in the other machine
presses the Release bu�on.
Once the other machine has been released, the
system will allow you to lower the load, and
therefore move the machine out of Overload, while
the mo�on will remain cut in an upward direc�on, to
prevent the Overload condi�on from being
increased.
Error Messages
While the RF Tandem Modems have a range of at least 100m, there might be situa�on where the link
between them may be lost.
If the Paired Tandem Link is lost, then
I31 Tandem Li� Interface Comms
will be shown on the Operator
Screen.
If there is a communica�on issue, and some transmi�ed data is missed, then
I32 Tandem Li� Interface
Checksum
will be shown on the Operator Screen.
In either case, the error will be shown and the Safe Working Load Percentage will be dropped to 66% of
whichever duty (Road or Rail) the system is in. If this puts the machine into an overload condi�on, the
appropriate mo�ons will be cut, and the alarm will sound.