![Giussani Techniques E-PRL Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/giussani-techniques/e-prl/e-prl_user-manual_2229561006.webp)
5
INITIAL LOCK PROGRAMMING WITHOUT ACCESS CONTROL FUNCTION
✓
Follow the procedure below if the MASTER key (red) does not include the Access Control feature
1.
Insert the MASTER key (red) WITHOUT ACCESS CONTROL FUNCTION (product code EMK-03)
A single fast blink of the green LED will flash ( ) to indicate the start of the key pairing procedure; remove the key from the
lock after the above signal has occurred.
2.
Insert a USER key (black) that you want to pair with the lock.
A single long blink of the green LED will flash ( ) to indicate the correct key combination; remove the key from the
lock after the above signal has occurred.
Repeat step 2 for each additional USER key (black) that you want to match to the lock.
Note: Inserting another key already in this step (step 2) will cancel the pairing by making the key unusable at the end of the
procedure (refer to section 1.3 under the heading, "Add and Delete Keys").
3.
After entering all the keys to be stored, re-insert the MASTER key (red) into the lock.
A single long blink of the green LED will flash ( ) to indicate the end of the pairing procedure; Remove the key from the
lock after the above signal has occurred.
4.
The programming procedure is now complete and all the USER keys (black) stored in the lock can now open the lock.
Caution: From now on, no MASTER key (red) other than the one used for the initial programming will be able to perform any
operation on the lock.
INITIAL LOCK PROGRAMMING WITH ACCESS CONTROL FUNCTION
✓
Lock Programming with Access Control requires:
•
MASTER Key (red) with access control function (product code EMK-00)
•
ACCESS CONTROL KIT (product code EPOD-00)
✓
Follow the procedure below to program the lock
1.
Before programming the lock and storing the USER keys (black), it is recommended to synchronize the USER keys (black) as
indicated in the "Access Control System" User Manual under the heading "Registration" of the keys "; If this step is not
completed, the USER keys (black) will not work, they will not be paired, and an error message will be shown via a blinking red
LED ( )
2.
Insert the MASTER key (red) into the lock with ACCESS CONTROL FUNCTION (product code EMK-02)
A single fast blinking of the green LED will flash ( ) to indicate the start of the key pairing procedure; Remove the key from
the lock after the above signal has occurred.
3.
Insert a USER key (black) or a DOWNLOAD key (blue) that you want to pair.
A single long blink of the green LED will flash ( ) to indicate the correct key combination; Remove the key from the lock
after the above signal has occurred.
Repeat step 2 for each additional USER key (black) or DOWNLOAD key (blue) that you want to pair.