INDEX 

 

General description 

 

 

 

 

 

 

 

 

 

p. 2 

 

System characteristics 

 

 

 

 

 

 

 

 

 

p. 2 

 

Key characteristics  

 

 

 

 

 

 

 

 

 

p. 2 

 

Lock characteristics 

 

 

 

 

 

 

 

 

 

p. 3 

 

Operating mode   

 

 

 

 

 

 

 

 

 

p. 3 

 

General lock assembly 

 

 

 

 

 

 

 

 

 

p. 3 

 

Rear rotation washer assembly 

 

 

 

 

 

 

 

    

p. 4 

 

Preparing the lock for initial programming 

 

 

 

 

 

 

 

p. 4 

 

Initial lock programming WITHOUT “ACCESS CONTROL”

 

 

 

 

 

 

p. 5 

 

Initial lock programming with “ACCESS CONTROL”

 

 

 

 

 

 

 

p. 5 

 

Opening the lock   

 

 

 

 

 

 

 

 

 

p. 6 

 

Add or delete keys 

 

Programmed lock initial setup 

 

 

 

 

 

 

 

p. 6 

o

 

Pair key to lock memory   

 

 

 

 

 

 

 

p. 6 

o

 

Eliminate key from lock memory   

 

 

 

 

 

 

p. 7 

 

Programmed lock already setup (open lock) with any USER key   

 

 

 

p. 7 

o

 

Pair key to lock memory   

 

 

 

 

 

 

 

p. 7 

o

 

Eliminate key from lock memory   

 

 

 

 

 

 

p. 7 

 

Reset lock with MASTER key 

 

 

 

 

 

 

 

 

p. 8 

 

Switching to ACCESS CONTROL FUNCTION 

 

 

 

 

 

 

 

p. 9 

 

DOWNLOAD key (with GSN-KEY Access Control Software) 

 

 

 

 

 

p. 9 

 

Loss/Key failure 

 

MASTER key 

 

 

 

 

 

 

 

 

 

p. 10 

 

USER key   

 

 

 

 

 

 

 

 

 

p. 10 

 

DOWNLOAD key 

 

 

 

 

 

 

 

 

 

p. 11 

 

Key battery 

 

 

 

 

 

 

 

 

 

 

p. 11 

 

Declaration of Conformity   

 

 

 

 

 

 

 

 

p. 12 

 

 

 

 

 

 

 

 

 

 

Manual Rev

 

Date

 

Description

 

 

01.07.2017

 

First issue

 

1

 

01.09.2017

 

Modified chapter “SWITCHING TO ACCESS CONTROL FUNCTION”

 

02.10.2017  Modified logs and quantity of keys that can be stored on the lock

 

03.11.2017  Insert 132° rotation washer 

17.01.2018  Modified the RESET procedure 

Содержание E-PRL

Страница 1: ...E PRL REPROGRAMMABLE ELECTRONIC LOCK MULTI CODE version User manual...

Страница 2: ...ck memory p 7 Programmed lock already setup open lock with any USER key p 7 o Pair key to lock memory p 7 o Eliminate key from lock memory p 7 Reset lock with MASTER key p 8 Switching to ACCESS CONTRO...

Страница 3: ...lectric shock resistant Self powered system that does not require an electrical system Encrypted and inviolable communication system Over 10 billion combinations Access control via the dedicated GSN K...

Страница 4: ...is supplied by the keys OPERATING MODE In the Multi Code version the MASTER key red allows the use of each lock with up to 300 USER keys black and or DOWNLOAD blue Each programmed lock will work only...

Страница 5: ...correct position for programming We recommended you perform the mechanical lock installation before programming For assemblies that require programming prior to mechanical installation contact Technic...

Страница 6: ...the USER keys black stored in the lock can now open the lock Caution From now on no MASTER key red other than the one used for the initial programming will be able to perform any operation on the lock...

Страница 7: ...e repeating the operation Attention in order to avoid an excessive consumption of the batteries contained inside each single key it is advisable once the key has been opened not to leave it in the loc...

Страница 8: ...MASTER key red into the lock the key used for initial lock programming 2 2 A single fast blink of the green LED on the MASTER key red indicates the start of the key pairing and cancellation process R...

Страница 9: ...ogramming waiting state and it can accept any MASTER key red for programming In order to reset the lock it is necessary to insert and extract the paired MASTER key red used for the initial programming...

Страница 10: ...ntrol System User Manual in the Key Recording section DOWNLOAD KEY WITH GSN KEY ACCESS CONTROL SOFTWARE The DOWNLOAD key is the key you need to download and history access log from the locks and to vi...

Страница 11: ...d bearing the CMC The MASTER COPY key red will emit a single fast blink of the green LED to indicate the start of the pairing procedure Remove the key from the lock after the above signal has occurred...

Страница 12: ...he time of purchase 1 1 Insert the MASTER key red into the lock the key used for initial lock programming 1 2 A single fast blink of the green LED on the MASTER key red indicates the start of the key...

Страница 13: ...requirements applicable to the type of product and required by telecommunications regulations in accordance with Directive 2014 30UE and 2011 65 EC using the rules published in the Official Journal of...

Отзывы: