SWITCHING TO ACCESS CONTROL FUNCTION
✓
The Access Control feature can be enabled at any time, in a configuration that originally was not anticipated, using the Access
Control Kit (EPOD-00 product code) and the use of a new MASTER key (Red) EMK-02.
✓
To upgrade your system follow the steps below:
1.
Insert the MASTER key (red) EMK-03 in the lock with the lock not enabled for access control.
MASTER key (red) will emit a single fast green blink of the LED ( ) to indicate the start of the pairing procedure; Remove the
key from the lock after the above signal has occurred.
2.
Insert the NEW MASTER key (red) EMK-02 enabled in the lock for access control.
MASTER key (red) will emit a single green fast blink of the LED ( ) to indicate the acquisition of the new key with the
consequent upgrade of the system; Remove the key from the lock after the above signal has occurred.
3.
Insert the NEW MASTER key (red) EMK-02 into the lock.
A single long green LED ( ) blink will flash from the NEW MASTER key (red) to indicate the end of the pairing procedure;
Remove the key from the lock after the above signal has occurred.
4.
Repeat the procedure for each lock
✓
After completion of the procedure, the NEW MASTER key (red) EMK-02will be paired to the lock and will be enabled for Access
Control; The MASTER key (red) previously paired will no longer be able to perform any operation on the lock.
✓
All previously paired USER keys (black) can only be used after the clock synchronization, as indicated in the "Access Control
System" User Manual in the "Key Recording" section.
DOWNLOAD KEY (WITH GSN-KEY ACCESS CONTROL SOFTWARE)
✓
The DOWNLOAD key is the key you need to download and history access log from the locks and to view them through the GSN-
KEY software.
✓
The DOWNLOAD key (blue) can contain up to 32,000 logged events in its memory. It is recommended that you delete events
from the key once they have been transferred to the GSN-KEY software.
✓
The lock can store up to 3.300 access events. Once the maximum memory capacity is reached, new events will overwrite the
old ones automatically
✓
In the
MULTI-CODE
version, the pairing of the DOWNLOAD key (blue) to the lock occurs in the same way as the USER keys
(black) are registered - See "ADDING OR ELIMINATING USER KEYS FROM LOCK"
✓
If the DOWNLOAD key (blue) has not been paired with the lock, it will not work and an error will be indicated with a single red
blink of the red LED ( )
✓
To download the history of access events from the lock
1.
Insert the DOWNLOAD key (blue) into the lock
Depending on the amount of data on the lock, long blink of the green LED will flash ( ) sequentially, with approximately
one second waiting between each.
2.
A single long blink of the green LED will flash ( ) to indicate the correct transfer of the data in the lock onto the DOWNLOAD
key. Pull the key out of the lock after the above indicated signal.
3.
If the DOWNLOAD key is extracted from the lock before completing the transfer of all the data in the lock, an error signal will
be output with a single fast blink of the red LED ( ). In this case, re-insert the DOWNLOAD key into the lock and retrieve the