SWITCHING TO ACCESS CONTROL FUNCTION 

 

The Access Control feature can be enabled at any time, in a configuration that originally was not anticipated, using the Access 
Control Kit (EPOD-00 product code) and the use of a new MASTER key (Red) EMK-02. 

 

 

 

To upgrade your system follow the steps below: 

 

1.

 

Insert the MASTER key (red) EMK-03 in the lock with the lock not enabled for access control. 
MASTER key (red) will emit a single fast green blink of the LED (       ) to indicate the start of the pairing procedure; Remove the 
key from the lock after the above signal has occurred. 

 

2.

 

Insert the NEW MASTER key (red) EMK-02 enabled in the lock for access control. 
MASTER  key  (red)  will  emit  a    single  green  fast  blink  of  the  LED  (        )  to  indicate  the  acquisition  of  the  new  key  with  the 
consequent upgrade of the system; Remove the key from the lock after the above signal has occurred.  
 

3.

 

Insert the NEW MASTER key (red) EMK-02 into the lock. 
A single long green  LED (              ) blink will flash from the NEW MASTER key (red) to indicate the end of the pairing procedure; 
Remove the key from the lock after the above signal has occurred. 
 

4.

 

Repeat the procedure for each lock 

 

 

After completion of the procedure, the NEW MASTER key (red) EMK-02will be paired to the lock and will be enabled for Access 
Control; The MASTER key (red) previously paired will no longer be able to perform any operation on the lock. 

 

 

All previously paired USER keys (black) can only be used after the clock  synchronization, as indicated in the "Access Control 
System" User Manual in the "Key Recording" section.

 

 

DOWNLOAD KEY (WITH GSN-KEY ACCESS CONTROL SOFTWARE) 

 

The DOWNLOAD key is the key you need to download and history access log from the locks and to view them through the GSN-
KEY software. 

 

 

The DOWNLOAD key (blue) can contain up to 32,000 logged events in its memory. It is recommended that you delete events 
from the key once they have been transferred to the GSN-KEY software. 

  

 

The lock can store up to 3.300 access events. Once the maximum memory capacity is reached, new events will overwrite the 
old ones automatically 

 

 

In the 

MULTI-CODE

 version, the pairing of the DOWNLOAD key (blue) to the lock occurs in the same way as the USER keys 

(black) are registered - See "ADDING OR ELIMINATING USER KEYS FROM LOCK" 

 

 

If the DOWNLOAD key (blue) has not been paired with the lock, it will not work and an error will be indicated with a single red 
blink of the red LED (            ) 

 

 

To download the history of access events from the lock  
 
1.

 

Insert the DOWNLOAD key (blue) into the lock 
Depending on the amount of data on the lock, long blink of the green LED will flash (          ) sequentially, with approximately 
one second waiting between each. 

 

2.

 

A single long blink of the green LED will flash (     ) to indicate the correct transfer of the data in the lock onto the DOWNLOAD 
key. Pull the key out of the lock after the above indicated signal. 
 

3.

 

If the DOWNLOAD key is extracted from the lock before completing the transfer of all the data in the lock, an error signal will 
be output with a single fast blink of the red LED (     ). In this case, re-insert the DOWNLOAD key into the lock and retrieve the 
data, awaiting the signal as indicated in step 2 before extracting the key. 

 
 
 

Содержание E-PRL

Страница 1: ...E PRL REPROGRAMMABLE ELECTRONIC LOCK MULTI CODE version User manual...

Страница 2: ...ck memory p 7 Programmed lock already setup open lock with any USER key p 7 o Pair key to lock memory p 7 o Eliminate key from lock memory p 7 Reset lock with MASTER key p 8 Switching to ACCESS CONTRO...

Страница 3: ...lectric shock resistant Self powered system that does not require an electrical system Encrypted and inviolable communication system Over 10 billion combinations Access control via the dedicated GSN K...

Страница 4: ...is supplied by the keys OPERATING MODE In the Multi Code version the MASTER key red allows the use of each lock with up to 300 USER keys black and or DOWNLOAD blue Each programmed lock will work only...

Страница 5: ...correct position for programming We recommended you perform the mechanical lock installation before programming For assemblies that require programming prior to mechanical installation contact Technic...

Страница 6: ...the USER keys black stored in the lock can now open the lock Caution From now on no MASTER key red other than the one used for the initial programming will be able to perform any operation on the lock...

Страница 7: ...e repeating the operation Attention in order to avoid an excessive consumption of the batteries contained inside each single key it is advisable once the key has been opened not to leave it in the loc...

Страница 8: ...MASTER key red into the lock the key used for initial lock programming 2 2 A single fast blink of the green LED on the MASTER key red indicates the start of the key pairing and cancellation process R...

Страница 9: ...ogramming waiting state and it can accept any MASTER key red for programming In order to reset the lock it is necessary to insert and extract the paired MASTER key red used for the initial programming...

Страница 10: ...ntrol System User Manual in the Key Recording section DOWNLOAD KEY WITH GSN KEY ACCESS CONTROL SOFTWARE The DOWNLOAD key is the key you need to download and history access log from the locks and to vi...

Страница 11: ...d bearing the CMC The MASTER COPY key red will emit a single fast blink of the green LED to indicate the start of the pairing procedure Remove the key from the lock after the above signal has occurred...

Страница 12: ...he time of purchase 1 1 Insert the MASTER key red into the lock the key used for initial lock programming 1 2 A single fast blink of the green LED on the MASTER key red indicates the start of the key...

Страница 13: ...requirements applicable to the type of product and required by telecommunications regulations in accordance with Directive 2014 30UE and 2011 65 EC using the rules published in the Official Journal of...

Отзывы: