![Giussani Techniques E-PRL Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/giussani-techniques/e-prl/e-prl_user-manual_2229561011.webp)
10
✓
To clear the history of access events in the lock memory
1.
After downloading the data provided by the DOWNLOAD key (blue) and without opening the lock, insert the DOWNLOAD key
(blue) for the second time in the lock.
A single fast blink of the green LED will flash ( ) followed by a single long red blink of the red LED ( ) indicating that all
previously logged events on the lock have been cleared
✓
To clear access data in the DOWNLOAD key memory (blue) you will need the ACCESS CONTROL KIT (refer to the Access Control
System User Manual for the process).
LOSS OR KEY FAILURE
✓
Each key is supplied with an Identification Card (Key Identifier) that has all the necessary data for any duplication in case of
failure or loss.
YOU ARE ADVISED TO STORE IT IN A SAFE PLACE AND TO NOT LOSE THE KEY IDENTIFIER
.
✓
✓
MASTER KEY
In the event of loss or failure of the MASTER key (red) it may be necessary to duplicate the key but only by presenting the key
identifier provided with the key at the time of purchase (see above)
✓
For replacement of lost or damaged MASTER keys (red), 2 MASTER keys will be delivered (red) identified on their respective
labels with:
1.
CMC
corresponding to the MASTER COPY key of the lost or damaged key
2.
CM
corresponding to the new MASTER key that will replace the lost or damaged one
1.
Insert the MASTER COPY key (red) in the lock together with the identification card bearing the "CMC"
The MASTER COPY key (red) will emit a single fast blink of the green LED ( ) to indicate the start of the pairing procedure;
Remove the key from the lock after the above signal has occurred
2.
Insert the NEW MASTER key (red) in the lock together with the identification card bearing the letter "CM"
The NEW MASTER key (red) will emit a single fast blink of the green LED ( ) to indicate the match of the new MASTER key
(red); Remove the key from the lock after the above signal has occurred
3.
Re-insert the NEW MASTER key (red) in the lock to close the replacement process.
The NEW MASTER key (red) will be emitted by a single long blink of the green LED ( ) indicating the end of the pairing
procedure; Remove the key from the lock after the above signal has occurred.
4.
Repeat the process for each lock
✓
After replacing the lock (s) and the NEW MASTER key (red) and the MASTER key lost or broken, as well as the MASTER COPY
key (red) will no longer be able to perform any operation on the lock
✓
USER KEY
In the event of loss or failure of one or more USER keys (black), that inhibits the lock function of the paired key, you may be
prompted to replace the USER key (black) may be required, but only by presenting the Key Identifier included with the key at the
time of purchase (see above)
In the case of system with access control function, before programming the lock and storing the new SUBSTITUTED USER KEY
(black), it is recommended to synchronize the new SUBSTITUTED USER KEY (black) as indicated in the "Access Control System"
User Manual under the heading "Registration" of the keys ".