Alarms
135
Code no. 550038
Rev. no. 16/1018
PB/PBP51, X20 MODEL ERROR
PB32, X13
ALM / Err0
Unidentified machine model
Probable cause:
Reading error in model identification bridges.
Lack of coherence between identification bridges and machine model
Fault in the machine's microprocessor
Procedure:
Disconnect the power supply from the machine and reconnect after five minutes.
If fault persists or is frequently repeated, disconnect the power supply and close the manual gas inlet valve
(machines heated with gas).
Contact Authorised Technical Services.
12.2. Expanded information on alarms related to the inverter
On PB/PBP51, X20 ironers, the alarm code is preceded by the description.
GENERAL INVERTER FAILURE
ALARM CODE
FAULT DESCRIPTION
PB/PBP51, X20
Fault 41, 42, 43
Inverter output missing phase
PB32, X13
U-41, 42, 43
PB/PBP51, X20
Fault 47
Inverter overloaded
PB32, X13
U-47
PB/PBP51, X20
Fault 48
Low voltage in inverter D.C. bus
PB32, X13
U-48
PB/PBP51, X20
Fault 49
Over voltage in inverter D.C. bus
PB32, X13
U-49
PB/PBP51, X20
Fault 50
Short-circuit in motor or on motor connection
PB32, X13
U-50
PB/PBP51, X20
Fault 52
Missing phase on inverter supply or too high voltage imbalance
PB32, X13
U-52
PB/PBP51, X20
Fault 55
Inverter overheated
PB32, X13
U-55
PB/PBP51, X20
Fault 56
Discharge from inverter output phase to ground
PB32, X13
U-56
PB/PBP51, X20
Fault 59
Overcurrent inverter
PB32, X13
U-59
PB/PBP51, X20
Fault **
Unidentified inverter failure
PB32, X13
U-**