Maintenance
143
Code no. 550038
Rev. no. 16/1018
13.7. Possible operational anomalies
ANOMALY
PROBABLE CAUSE
ACTION
ROLL ENCRUSTATIONS
Laundry excessively mineralised
Adjust the washing process.
Incorrect use of washing products
Delicate laundry pieces ironed at too
high a temperature or insufficient
speed
Adjust temperature and speed to
the fabric type.
IRONED LINEN
MOISTURE TOO HIGH
Excessive residual damp in the fabrics
being ironed
Modify the extract process.
Excessive ironing speed
Reduce speed.
Temperature defect
Raise temperature.
LINEN ROLLING UP ON
THE ROLL
Dirt in the detachment springs
Clean springs.
Low pressure in the detachment
springs
Call the ATS.
Laundry insufficiently rinsed
Adjust the washing process.
Static electricity
Add anti-static products to wash
process.
Check
the
machine’s
earth
connection.
INCORRECT SPEED ON
THE ROLL MOTOR
Inverter breakdown
Call the ATS.
Fault on the encoder
Call the ATS.
TOO RED FLAME (GAS
VERSION)
Deficient gas supply
Correct supply.
Faulty air intake filter
Clean filter.
THE BURNER CAN NOT
BE IGNITED (GAS
VERSION)
Manual gas flow valve closed
Open manual gas flow valve.
Deficient gas supply
Correct supply.
Gas ignition system defective or
ignition electrodes misplaced
Call the ATS.
POOR FLAME SPREAD
(GAS VERSION)
Deficient gas supply
Correct supply.
Blocked burner holes
Call the ATS.
LINES ON THE LINEN
Ironed linen moisture too high
Adjust speed or temperature.
Laundry introduced incorrectly
Stretch laundry pieces as they are
being introduced.
FAULTY LINEN FOLDING
Faulty length selection
Check the selection
Static electricity
Add anti-static products to wash
process.
Check
the
machine’s
earth
connection.
Содержание PB32 Series
Страница 52: ...Technical data 52 Code no 550038 Rev no 16 1018 4 9 2 PB PBP51 X20 models Fig 4 3 ...
Страница 98: ...Operating and use Inteli Control 98 Code no 550038 Rev no 16 1018 MANUAL MODE AUTOMATIC MODE ...
Страница 114: ...Operating and use Logi Control 114 Code no 550038 Rev no 16 1018 8 5 2 Advanced mode flowchart ...