16
Information page
On the information page, all current messages (alarms, faults, etc.) are displayed
according to the following priority:
• Messages from another security area
• Messages about active faults that need to be cleared.
• Messages about ignored faults that must be acknowledged
• Open detectors
The i-LED
The LED indicates if a message is available or if it still must be acknowledged.
Example
The batteries have to be changed on a wireless magnetic contact.
1. The -LED flashes yellow. Press the
button: "Low battery" is displayed.
2. Open the housing of the wireless magnetic contact. The tampering contact is
triggered.
3. Change the batteries in the wireless magnetic contact according to the
instructions for use and close the housing again.
4. Press the
button and go to the info page.
5. Acknowledge the message using the Administrator PIN.
3
PIN correct: the message was acknowledged successfully and deleted from
the info page.
LED
Meaning
off
No messages available.
flashes yellow
New, unread messages are available.
lights up yellow Messages have already been read.
lights up green Info page turned on.
Information page
Содержание Alarm Connect
Страница 1: ...Gira security system Alarm Connect Operating instructions Wireless operating unit...
Страница 2: ......
Страница 45: ...45...
Страница 46: ...46...
Страница 51: ...51...