background image

 

12

I am at home - switch on "internally arm"

1. Press the 

 key and enter the user PIN.

3

PIN correct: The 

 symbol appears on the Display and the 

 button lights 

up constinously yellow. The security area is switched to "Internally armed".

You can now move freely in the security area. If you still unintentionally open a 
secure window for example, the pre-alarm (signal tone) will sound on the 
wireless operating unit so that you have enough time to disarm the security area.

Disarm

1. Press the 

 key and enter the user PIN.

3

PIN correct: Erase the 

 symbol in the display and the 

 button. The 

security area is disarmed.

Arm/disarm

Содержание Alarm Connect

Страница 1: ...Gira security system Alarm Connect Operating instructions Wireless operating unit...

Страница 2: ......

Страница 3: ...Display and button assignment Key see the drop down menu on the last page 22 30 Display and button assignment...

Страница 4: ...ted 11 I am home Activate Internally armed 12 I am not home Activate Externally armed 13 Manual alarms 14 Trigger alarm 14 Deactivate alarm 14 When do I trigger the panic alarm 15 When do I trigger th...

Страница 5: ...in the display 29 7 3 Change the volume of the signal tones 30 7 4 Change the switch off delay of the backlight permanently switch on or off the display 31 7 5 Assign change or reset the user PIN and...

Страница 6: ...menu item Change PIN and confirm with OK 6 Enter a new four digit PIN 7 Confirm with the new PIN 8 Press the key to exit the menu Administrator PIN The factory assigned Administrator PIN 0001 must be...

Страница 7: ...ctions are only available to a limited extent Permanent illumination of the display is not possible In sleep mode alarm and fault messages are only signaled by the flashing status LED three second int...

Страница 8: ...i tion LED Meaning Inactive green Everything ok yellow Fault e g tampering battery low etc red Alarm e g panic alarm fire alarm etc Internally armed green Everything ok yellow Fault e g empty battery...

Страница 9: ...ntrusion into an armed security area triggers an alarm Example An object with two independent security areas each security area has a separate entrance The alarm control unit Connect is located in Sec...

Страница 10: ...xternally armed a distinction is also made between the inevitability factor and the lock function Inevitability factor External activation is implemented by means of the activation device key switch V...

Страница 11: ...rming can be found in the system description of the Alarm Connect security system PIN entry The following always applies when entering the PIN After entering the 4 digit PIN the wireless control unit...

Страница 12: ...d to Internally armed You can now move freely in the security area If you still unintentionally open a secure window for example the pre alarm signal tone will sound on the wireless operating unit so...

Страница 13: ...Check on the info page to see what has prevented the arming process e g fault open detector etc Disarm 1 When entering the Externally armed security area a pre alarm signal tone for the duration of t...

Страница 14: ...rvice call factory code 777 Regardless of the alarm type the following always applies Enter the code for the desired alarm and confirm with the OK button The corresponding alarm is activated and shown...

Страница 15: ...ere are people in other security areas The presence alarm Requirement The presence alarm function has been activated and configured in the project The security area user must confirm his presence with...

Страница 16: ...ct 1 The LED flashes yellow Press the button Low battery is displayed 2 Open the housing of the wireless magnetic contact The tampering contact is triggered 3 Change the batteries in the wireless magn...

Страница 17: ...Intruder alarm under Externally armed Intruder alarm under Internally armed Fire alarm Panic alarm Service alarm Presence alarm Deactivate alarm Deactivate alarm Ongoing fire alarm Deactivate alarm b...

Страница 18: ...are displayed on the info page Alarm device open with Bypass Bypass function see page 25 Doorbell switched off Doorbell function see page 27 Internally armed The security area is switched to Internall...

Страница 19: ...rofessional company Power failure Check the fuse in distribution box If necessary contact the network provider or professional company Error transmission path 1 or 2 Contact the professional company E...

Страница 20: ...repeater The batteries might be dead Contact the profes sional company Symbol Number Meaning Not visible The security area is either disarmed or switched to Internally armed Visible The security area...

Страница 21: ...may result in a risk of explosion Replacing the battery Replace the battery as soon as the low battery display appears in the display of the wireless operating unit Always change out all four batteri...

Страница 22: ...ach the wireless operating unit to the mounting frame attach from above and screw on from below until you hear a click Acknowledge all messages on the info page Technical data Battery Type CR 123A lit...

Страница 23: ...access rights of the individual user roles can be found in the overview on the next page Installer s temporary activation The installer is required for the duration of the installation and maintenanc...

Страница 24: ...1 Bypass x x 2 Button lock 30 seconds x x x 3 Display brightness x x x 4 Doorbell x x x 5 Service info x x x 6 Event memory x x x 7 Extended menu x x 7 1 Date and time x x 7 2 Time display on the oper...

Страница 25: ...devices and messages open detectors devices with dead batteries etc are displayed 3 Use the arrow key to navigate to the device to be bypassed 4 Press the OK button again The following display appear...

Страница 26: ...venting arming 6 Press the key to exit the menu The following display appears 7 If faults were bypassed the fault messages must be acknowledged on the info page 8 The security area can now be armed de...

Страница 27: ...ily opened more frequently e g an open house or similar and the signal tone disturbs you 1 Pull up the settings menu and press the key to navigate to menu item Doorbell 2 Press OK and open the menu it...

Страница 28: ...ess the key to navigate to menu item service information 2 Press OK and open the menu item Here you ll find contact information of the professional company that installed the Alarm Connect security sy...

Страница 29: ...ime in the display 1 Pull up the extended menu and press the key to navigate to the submenu Operating unit time display 2 Press OK and open the menu item 3 Select enabled or disabled and confirm the s...

Страница 30: ...and press OK to confirm 4 Press the and keys to set the volume and confirm with ok 5 Press the key to exit the menu Signal tones on the wireless operating unit The volume of the signal tones for the...

Страница 31: ...seconds from 10 to 240 seconds the backlight is switched off automatically The time is changed using the and keys and then confirmed with the OK key Factory default 30 seconds Display continuously on...

Страница 32: ...te to the submenu User management then confirm by pressing OK 2 Press the key and select a user then press ok to confirm 3 Press the key to navigate to Change PIN and confirm with ok 4 nter a 4 digit...

Страница 33: ...d 2 Press the key and select a wireless hand held transmitter then press ok to confirm 3 Select enabled or disabled and confirm the selection with the OK button 4 Press the key to exit the menu 7 7 Ch...

Страница 34: ...key to navigate to the submenu item Software version 2 Press the ok button The software version is displayed 7 10 Resetting the wireless operating unit You can reset all local settings e g set display...

Страница 35: ...the alarm will be deactivated again manually no alarm can be triggered The manual alarms have been activated and configured in the project Contact the professional company and have the appropriate ala...

Страница 36: ...re are explained for the usage of the contractual object software You are declaring your consent with the terms of this agreement through the acceptance of this agreement and by installing the Gira se...

Страница 37: ...f the corresponding source codes to the licensee and third parties on request within 36 months after conclusion of contract against payment of the shipping costs after invoicing by the Licensor 2 Righ...

Страница 38: ...ed to transfer the Alarm Connect software and the license key for the usage of the software to third parties if i the licensee has removed the Alarm Connect software backup copies and the required lic...

Страница 39: ...oftware and the documentation either provided in printed form or as well as online documentation will be provided to the licensee as amended The period of the guarantee for the Alarm Connect Software...

Страница 40: ...aided in the fulfilling of the contract Furthermore the exclusion of liability does not apply for damages arising from injury to life limb and health and for assumed guaranties guarantee liability by...

Страница 41: ...licensee does not have a general jurisdiction within the Federal Republic of Germany 8 Collateral Agreements and Changes to the Contract Collateral agreements und changes to contract require to be in...

Страница 42: ...0 28 GPLv3 dropbear 2015 67 http matt ucc asn au dropbear releases MIT BSD 2c like BSD 2c eeprog 0 7 6 http www codesink org download GPLv2 expat 2 1 0 http downloads sourceforge net project expat ex...

Страница 43: ...re memtester old versions GPLv2 mtd 1 5 2 ftp ftp infradead org pub mtd utils GPLv2 ncurses 5 9 http ftp gnu org pub gnu ncurses MIT with advertising clause netcat 0 7 1 http downloads sourceforge net...

Страница 44: ...6 2 https www kernel org pub linux utils util linux v2 26 GPLv2 BSD 4c libblkid and libmount LGPLv2 1 libuuid BSD 3c websocketpp 0 7 0 https github com zaphoyd websocketpp BSD xerces 3 1 2 http archiv...

Страница 45: ...45...

Страница 46: ...46...

Страница 47: ...tonlock30 s Settings Doorbell Settings Bypass Settings Function must be activated at the project Then visible for all Only visible for Administrator Installer Display only visible if corresponding dat...

Страница 48: ...entry Volume Volume Extended menu Date and time Extended menu Operating unit time display Extended menu Activated Zeitanzeige Bedieneinheit Deactivated Change date and time Date and time Backlight Ext...

Страница 49: ...guage selection Extended menu Extended menu Deutsch List of languages Administrator User management Handheld transmitter List of hand held transmitters Activated Testoperation Deactivated User User ma...

Страница 50: ...age 11 Negative feedback also see page 11 Button Meaning Settings menu Info page Jump back to the level leave the view Pull up the info page also see page 16 Pull up the settings menu also see page 23...

Страница 51: ...51...

Страница 52: ...KG Electrical installation systems P O Box 1220 42461 Radevormwald Germany Phone 49 2195 602 0 Fax 49 2195 602 191 info gira com www gira de Legal notice Picture credits schmitz Visuelle Kommunikatio...

Отзывы: