background image

34

LED indicators on BUS devices

The LEDs of the hands-free feature, Comfort with receiver, 
surface-mounted hands-free feature and surface-mounted 
gong home stations indicate the system status:

LED/button

System status

 or 

flashes

Programming mode active – call-buttons and/or 
gong not yet assigned

 or 

 

lights up

Programming mode active – at least one call 
button is already assigned to the home station or 
the gong 

 

lights up

Programming mode active – home station 
memory of occupied by 10 call buttons
(Occupied on the surface-mounted hands-free 
feature home station with 15 call buttons)

 

lights up 
long/short

Programming mode active
long = automatic door opener enabled 
short = automatic door opener disabled

 

lights up

Automatic door opener activated

 

flashes 2 min

Comfort home station with receiver:
signals incoming call

 

lights up

Comfort home station with receiver:
a call is in progress

 

flashes 2 min

Hands-free feature and surface-mounted hands-
free feature home station: signals incoming call

 

lights up

Hands-free feature and surface-mounted hands-
free feature home station: a call is in progress

 

lights up

Call tone is deactivated

Содержание 1287 00

Страница 1: ...Operating Instructions System Manual Audio control device 1287 00...

Страница 2: ......

Страница 3: ...home station 20 House divided into several flats Assigning door station call buttons to home stations 21 Assigning door opener 23 Automatic door opener 25 Assigning home station via floor call button...

Страница 4: ...tton A call tone differentiation is made between the following calls at the home stations door call initiated by call button floor call initiated by floor call button internal call initiated by call b...

Страница 5: ...ections is 700 m A maximum of 30 devices may be connected to each wiring section The maximum cable lengths of the individual sections from the control device to the last device are dependent on the ca...

Страница 6: ...6 Installation scenario topologies Branch line solution Outdoor station Control unit audio 2 2 2 Door opener WS 3 WS 2 WS 1 2 2 2 ET 2 ET 2 ET 2 2 2 ET Floor call button WS Home station...

Страница 7: ...the advantage of not requir ing the installation of a video distributor should video compo nents be retrofitted at a later time Outdoor station Control unit audio Door opener WS 3 WS 2 WS 1 2 2 2 ET...

Страница 8: ...he flush mounted door station with 3 gang call button 1 Door communication bus coupler 2 Audio connection cable 3 Speech insert 4 TX_44 cover frame bottom section not in scope of supply 5 Door speaker...

Страница 9: ...door station is pre sented in the example of the surface mounted door station with 3 gang call button 1 Housing bottom section 2 3 gang call button 3 Speech cover plate 4 Cable inlet 5 Sealing ring 6...

Страница 10: ...the example of the Comfort home station with receiver 1 Receiver insert 2 Empty insert 3 Audio connection cable 4 Door communication bus coupler 5 Cover frame not included in scope of supply 6 Operat...

Страница 11: ...e home station is shown in the following example 1 Mounting plate 2 Fixing holes for wall mounting 3 2 gang cover frame without crossbar cover frame not included in scope of supply frameless installat...

Страница 12: ...nec tion as the polarity of the door communication bus is neutral Floor call button ET With home stations any push button NO contact can be con nected to the ET terminals as the floor call button With...

Страница 13: ...be powered via the 2 wire bus System The flush mounted inserts are connected to each other with the 6 pole audio connection cable via these connectors Video The door communication bus coupler is conne...

Страница 14: ...lel provision of door opener control including power supply 12 V AC 1 6 A of the door opener power supply of a TC gateway activation of the programming mode from the entire door communication bus syst...

Страница 15: ...two functions 1 Activating door opener programming mode If the T r ffnerprogr button is pressed for 3 seconds while the system is in programming mode the door opener programming mode is activated see...

Страница 16: ...uits and overloading on the bus line The overload protection is activated if for example the bus line is short circuited due to an installation error or too many bus devices bus loads are connected Th...

Страница 17: ...2 V 160 mA 12 V AC The 12 V AC output is used to supply power to the door opener power consumption of the door opener is max 1 6 A or the telecommunication gateway Door opener relay 5 6 7 8 5 6 7 8 A...

Страница 18: ...ed voltage AC 230 V 50 Hz Secondary rated voltage SELV 26 V DC 2 V Secondary rated current 160 mA continuous load Overload deactivation from approx 350 mA 550 mA peak load max 5 seconds Power 47 VA Pr...

Страница 19: ...rox 7 minutes Exiting programming mode 1 Briefly press the Systemprog button on the control device to exit the programming mode The yellow LED goes out Start up documentation For documentation on the...

Страница 20: ...short acknowledgement tone A long acknowledgement tone indicates successful assignment Three short acknowledgement tones indicate faulty assignment The memory of the home station may already be occupi...

Страница 21: ...ment tone 3 Go to the home station whose call button is the first one you pressed at the door station Press the button on this home station for 3 seconds until you hear a short acknowledgement tone A...

Страница 22: ...you hear a short acknowledgement tone A long acknowledgement tone indicates successful assignment 6 After you have assigned all the home stations press the Systemprog button on the control device to e...

Страница 23: ...ve door station as follows 1 Press the Systemprog button on the control device for 3 seconds to start programming mode see Page 19 2 Press the T r ffnerprogr button on the control device for 3 seconds...

Страница 24: ...nt tone A long acknowledgement tone confirms successful assignment The door opener is controlled for the set time To assign additional door stations to the same door opener repeat Step 4 at the next d...

Страница 25: ...disabling automatic door opener function 1 Press the Systemprog button on the control device for 3 seconds to start programming mode see Page 19 2 Simultaneously press the buttons and on the home sta...

Страница 26: ...continuously The door opener is automatically operated after a door station call button is pressed Deactivating automatic door opener 1 Simultaneously press the buttons and on the home station for app...

Страница 27: ...ou hear a short acknowledgement tone You will hear a long acknowledgement tone 3 Go to the floor call button of the home station to be assigned Press the floor call button for 3 seconds until you hear...

Страница 28: ...ent tone You will hear a long acknowledgement tone 3 Go to the first home station Press the button for 3 seconds until you hear a short acknowledgement tone A long acknowledgement tone indicates succe...

Страница 29: ...econds Hold down the button for another 3 seconds until you hear a long acknowledgement tone 3 Press the button on home station 2 for 3 seconds until you hear a short acknowledgement tone A successful...

Страница 30: ...You will hear a long acknowledgement tone 3 Press the button on home station 2 for 3 seconds until you hear a short acknowledgement tone A long acknowledgement tone indicates successful assignment Th...

Страница 31: ...nds You will hear a brief acknowledgement tone after 3 seconds Hold down the button for another 3 seconds until you hear a long acknowledgement tone The long acknowledgement tone confirms the successf...

Страница 32: ...ming button T r ffnerprogr flashes rapidly 3 Press the Systemprog button on the control device to exit the programming mode Door opener at switching actuator To delete an existing assignment between t...

Страница 33: ...call buttons on the door station one after another in the sequence of the first start up for 3 seconds to restore the assignments The replacement and the old assignment of call buttons is restored wit...

Страница 34: ...y of occupied by 10 call buttons Occupied on the surface mounted hands free feature home station with 15 call buttons lights up long short Programming mode active long automatic door opener enabled sh...

Страница 35: ...mounted hands free feature home station no call buttons at the door or home station were pressed beforehand all previously pressed call buttons were already assigned to other home stations Acknowledg...

Страница 36: ...36 Table for start up documentation Call button Number Name Home station Name Location Floor Taught in Meier 2nd floor left living room...

Страница 37: ...37 Call button Number Name Home station Name Location Floor Taught in...

Страница 38: ...require ments via the specialist trade Please submit or send faulty devices postage paid together with an error description to your responsible salesperson spe cialist trade installation company elec...

Страница 39: ...39...

Страница 40: ...Gira Giersiepen GmbH Co KG Elektro Installations Systeme Postfach 1220 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 191 www gira de info gira de 10 41 05 21 19 11...

Отзывы: