Page 8
Due to continuous product research and development,
the information contained herein is subject to change without notice.
www.stoddart.com.au
www.stoddart.co.nz
IMPORTANT
DO NOT install unit under a bench.
Under Bench installation will void warranty
2.2.Positioning
• The oven must be installed under an extraction canopy that meets AS 1668.2.
• Have a smooth, level floor which can bear the weight of the appliance at full load
• Have a room temperature above +4°C with a maximum humidity of 70%;
• Comply with the regulations in force in terms of safety in the workplace and the systems;
• Not contain potentially explosive materials or substances;
• Be dedicated to food preparation. In addition, a gas-fired appliance requires, by law, rooms with a surface area and ventilation that are
suitable for the power of the oven and that have a means of externally evacuating flue gases
• Please consult national and local standards to ensure that your unit is positioned and ventilated in accordance with any existing
requirements
• Do not allow cables or other items to rest/hang over the exhaust vents
• Do not install unit under a bench
• No equipment is to be installed/placed on the Service compartment (top of oven) excluding stacked applications using a Stoddart
stacking kit and/or Stoddart Recirculating Hood. The service compartment must be easily accessible. Failure to adhere may add service
costs due to lack of access.
2.0 Installation
The sides of the Combi oven must have the following minimum clearances:
Heat Source
500mm clearance from another heat source, in order to protect the oven
components.
For distances under 500mm, it is mandatory for Stoddart heat shields to be
fitted (for a minimum distance of 50mm from the surface of the oven). Failure
to adhere to minimum clearances may void the oven warranty.
Non-Heat Source
50mm clearance from a non-heat source to the surface of the oven. Failure
to adhere to minimum clearances may void the oven warranty.
WALL
Hea
t Shield
Hea
t Shield
50mm
500mm
500mm
HEAT
SOURCE
HEAT
SOURCE
OVEN
WALL
50mm
50mm
50mm
HEAT
SOURCE
HEAT
SOURCE
OVEN
WALL
50mm
OVEN
50mm
50mm
NON - HEAT
SOURCE
NON - HEAT
SOURCE
2.2.1 General Information
2.2.2 Spacing
Heat Source
Heat Source With Heat Shield
Non - Heat Source