Giorgio Bormac ICF-120 Plus Скачать руководство пользователя страница 2

 
 

 

UM Ovens and Incubators EN rev. 0 31.05.2021 

Forced air and natural convection 

ovens

, multifunctional with microprocessor temperature controller. 

Model 

Description 

Temperature range 

TCN-30 Plus 

Natural convection oven 30L (maximum volume) 

Room temperature from + 5 °C to + 200°C 

TCN-50 Plus 

Natural convection oven 50L (maximum volume) 

Room temperature from + 5 °C to + 300 °C 

TCN-115 Plus 

Natural convection oven 115L (maximum volume) 

Room temperature from + 5 °C to + 300 °C 

TCN-200 Plus 

Natural convection oven 200L (maximum volume) 

Room temperature from + 5 °C to + 300 °C 

TCF-50 Plus 

Air forced oven 50L (maximum volume) 

Room temperature from + 10 °C to + 300 °C 

TCF-120 Plus 

Air forced 120L (maximum volume) 

Room temperature from + 10 °C to + 300 °C 

TCF-200 Plus 

Air forced 200L (maximum volume) 

Room temperature from + 10 °C to + 300 °C 

TCF-400 Plus 

Air forced 400L (maximum volume) 

Room temperature from + 10 °C to + 300 °C 

 

Forced air and natural convection 

incubator

s, multifunctional with microprocessor temperature controller. 

Model 

Description 

Temperature range 

ICN-16 Plus 

Natural convection incubator 16L (maximum volume) 

Room temperature from + 5 °C to + 70 °C 

ICN-35 Plus 

Natural convection incubator 35L (maximum volume) 

Room temperature from + 5 °C to + 70 °C 

ICN-55 Plus 

Natural convection incubator 55L (maximum volume) 

Room temperature from + 5 °C to + 70 °C 

ICN-120 Plus 

Natural convection incubator 120L (maximum volume) 

Room temperature from + 5 °C to + 70 °C 

ICN-200 Plus 

Natural convection incubator 200L (maximum volume) 

Room temperature from + 5 °C to + 70 °C 

ICF-120 Plus 

Air forced incubator 120L (maximum volume) 

Room temperature from + 5 °C to + 80 °C 
(sterilisation special program at 130°C) 

ICF-200 Plus 

Air forced incubator 200L (maximum volume) 

Room temperature from + 5 °C to + 80 °C 
(sterilisation special program at 130°C) 

ICF-400 Plus 

Air forced incubator 400L (maximum volume) 

Room temperature from + 5 °C to + 80 °C 
(sterilisation special program at 130°C) 

 

Producer: 
 

Sozhou Being Medical Device CO., LTD 
NO.108 Gongxiang RD Qiandeng Town 
Kunshan China 

Drafting by the agent: 
 

Giorgio Bormac s.r.l. 
Via della Meccanica, 25 
41012 Carpi (MO) - ITALY 
VAT n. IT02309180368 
 
Tel. +39 059 653274 
Fax +39 059 653282 
E-mail [email protected] 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание ICF-120 Plus

Страница 1: ...OVENS and INCUBATORS User manual...

Страница 2: ...troller Model Description Temperature range ICN 16 Plus Natural convection incubator 16L maximum volume Room temperature from 5 C to 70 C ICN 35 Plus Natural convection incubator 35L maximum volume Ro...

Страница 3: ...gns 5 Symbols of obligation 5 2 GENERAL SAFETY INSTRUCTIONS 6 3 CE MARKING DATA 8 4 CONTENT OF PACKAGE 9 5 TRANSPORTATION 9 Instructions for safe transportation 9 Transportation of an already used ove...

Страница 4: ...Cycle functions 15 Repetition of a selected program 15 Delay starts function 16 12 INTRODUCTION OF SAMPLES INTO OVEN INCUBATOR 16 Limit temperature for sample protection 16 Restart mode after absence...

Страница 5: ...ions or incorrect results due to failure to comply with them Read entirely and carefully this manual and be sure to familiarize with the tool before starting to work with it This manual must be kept n...

Страница 6: ...surfaces Danger of damage to health caused by toxic substances Danger of injury from overturning of objects Risk of injury from lifting heavy objects Danger of environmental damage Danger of corrosio...

Страница 7: ...y where there is no risk of explosion Do not keep air solvent mixtures or explosive dusts nearby Never introduce materials into the instrument that are explosive or flammable at the selected operating...

Страница 8: ...f each other Always fix 2 stacked ovens with the fixing plates provided Risk of injury Risk of slipping or overturning and risk of damage to the instrument The instrument must be lifted by 2 people Th...

Страница 9: ...ors EN rev 0 31 05 2021 3 CE marking data Argolab instruments are manufactured in compliance with Directive 2006 42 EC and the relevant Community Directives applicable at the time of placing on the ma...

Страница 10: ...rtation ATTENTION Risk of injury of slipping or overturning and risk of damage to the instrument The instrument must be lifted by 2 people The instrument must be transported in its original packaging...

Страница 11: ...rmitted storage temperature is 10 C to 60 C The maximum permitted storage humidity is 85 RH without condensation 7 First installation Getting started The oven should be installed in following conditio...

Страница 12: ...11 UM Ovens and Incubators EN rev 0 31 05 2021 8 Instrument parts Display and commands Display Adjustment keys ON OFF Key Opening closing handle...

Страница 13: ...mperature variation at 150 C 0 3 C 0 3 C 0 4 C 0 5 C Heating time at 150 C 20 min 24 min 30 min 50 min Timer 99 59 hh min e 99 59 hh min e 99 59 hh min e 99 59 hh min e Safety class 3 1 3 1 3 1 3 1 Po...

Страница 14: ...at 37 C 40 min 45 min 55 min Timer 99 59 hh min e 99 59 hh min e 99 59 hh min e Safety class 3 1 3 1 3 1 Power supply power 230 V 600 W 230 V 700 W 230 V 1500 W Internal dimensions L A P 520 x 530 x 4...

Страница 15: ...using the buttons in H High M Medium L Low otherwise go to STEP 2 STEP 2 Use the and SHIFT keys to set the temperature value of the second working STEP Briefly press the SET PROG button to confirm the...

Страница 16: ...e this operation has been carried out the word Lk lock appears in the top right hand corner of the display in place of the word TIME next to the digits 0000 password Here below you can find the passwo...

Страница 17: ...mit for sample protection The instrument foresees the possibility of limiting the maximum working temperature to protect the samples from an incorrect temperature setting of the heating cycle Follow t...

Страница 18: ...ormal and therefore reducing the AL value excessively would risk causing the instrument to go into alarm frequently and unnecessarily Follow the instructions in paragraph 10 and use the keys to set th...

Страница 19: ...corrosive DANGER Risk of electric shock and death DO NOT spray water or cleaning agents onto the interior and exterior surfaces Switch off the main switch and pull out the mains plug before cleaning D...

Страница 20: ...does not apply to any product or parts thereof that have been damaged due to incorrect installation improper connection misuse accident or abnormal operating conditions No liability is accepted for d...

Отзывы: