ENGLISH

Statements

•  Thanks for purchasing the product.

•  To ensure correct usage, please read the User Manual carefully before using this product.

•  Please keep the User Manual properly where convenient to read.

•  The company takes no responsibilities or provides no free maintenance for any abnormal phenomena or damage due to users 

not following the User Manual to use, maintain and store.

•  The company reserves final explanation right to this manual.

Chapter 1 
PRECAUTIONS

Please read the user manual carefully in order to ensure safe use.

 

Warning

•  Prompting the operations with danger or unsafe, if continue operating, it may cause death, severe body injury or property loss.

Attention

•  Emphasizing important notices, instructions or explanations for better use.

 

Warnings

•  Please follow doctors' advice about medication species, dosage and usage. Otherwise it may cause symptomatic deterioration.

•  Please follow the specified operation methods in the user manual, otherwise it may cause operation failure.

•  The accessories of device are designed for single use, do not reuse the accessory otherwise it may cause cross infection.

•  For the first time of using this device or if medication cup is unused for a long time, medication cup and mask must be cleaned 

and disinfected. Otherwise, it may cause bacterial reproductive infection.

•  Each user must use the accessory separately, otherwise it may cause cross infection.

•  Please clean the accessories after disinfection, otherwise patient may inhale the residual disinfectant, which may cause symp-

tomatic deterioration.

•  Used medication can't be reused, please change new medication for every treatment. Otherwise patient may be infected by 

varieties of bacteria, causing symptomatic deterioration.

•  Do not use the device to inhale water, otherwise it may cause symptomatic deterioration.

•  Do not use the device at ambient temperature above 40°C. Otherwise it may cause nasal mucosa injury or device failure.

•  Do not clean the main body in water or drop it into water or store the device in humid environment. Otherwise it may cause 

device failure.

•  Please clean the device after use, and dry it immediately after cleaning.

  Otherwise patient may be infected by varieties of bacteria.

•  Please keep the device out of the reach of children and people with mental illness. Otherwise it may cause danger of swallow-

ing small parts.

•  Do not use the device near flammable or explosive gas or anesthetic mixture. Otherwise it may cause personal injury.

•  Do not wrap the power cord around children's neck or other sensitive areas, or it may cause asphyxia.

•  The mask of this equipment is made of PVC material. The material passed the relevant test. After assessment, there is no 

unacceptable risks.

•  This device should not be used where it is difficult to disconnect the power supply device.

•  If the storage temperature is lower or higher, please leave the equipment in normal working environment for more than 1 hour, 

until it is ready for intended use.

•  It is not allowed to modify the equipment or it may cause damage to the equipment

Attention

•  If the device can't shutdown automatically when medication is exhausted, please immediately press the "ON/OFF" button to 

tum off, in order to avoid damage to the nebulizing sheet. Refer to Chapter 6 Troubleshooting.

•  Clean medication cup after each use. Otherwise, the device will not work normally.

•  When cleaning medication cup, do not directly place the device under tap water to prevent water from entering the device.

•  Do not use this product near high-frequency electromagnetic transmitters and other high-frequency electronic products.

•  Keep the device vertical as much as possible during use.

•  Prevent the main unit and medication cup from falling or being subjected to severe impact.

•  Do not touch the metal mesh of nebulizing sheet with a cotton swab or other sharp objects. Otherwise, the device may not work.

•  This product is subject to the guidance of a doctor. Patient who has sensitive parts with contusion, bums, inflammation, and 

facial/oral trauma should avoid using the device. If you feel uncomfortable during use, please stop using immediately and 

consult a doctor.

•  Do not mix different types of dry batteries.

•  Ensure that a guardian is present when used by children.

•  Do not store or carry the device with medication in the medication cup.

•  Disposal of waste main parts and accessories shall follow the local government regulations.

•  The use of this product is different from the laryngeal and nasal mucosa humidification equipment.

•  This product cannot be used in respiratory anesthesia systems and ventilator systems.

•  Please take batteries out if you won't use the device for long time.

•  The device service life is 3 years (excluding consumables).

•  The accessories are disposable, the device is sterilized by ethylene oxide, please check the packaging carefully before use, 

stop using it and contact with suppliers if there is obvious damage.

•  If necessary, provide circuit diagrams, components lists and necessary information for maintenance, please contact with suppliers.

Содержание 28066

Страница 1: ...TTENTION The operators must carefully read and completely understand the present manual before using the product AVIS Les op rateurs doivent lire et bien comprendre ce manuel avant d utiliser le produ...

Страница 2: ...thetic mixture Otherwise it may cause personal injury Do not wrap the power cord around children s neck or other sensitive areas or it may cause asphyxia The mask of this equipment is made of PVC mate...

Страница 3: ...batteries is DC3V 2 3 Operational environment Temperature 5 C 40 C Humidity 15 90 Atmospheric pressure 700hPa 1060hPa Attention This product is not suitable for use in strong electromagnetic interfer...

Страница 4: ...cup to the main unit be sure to install it properly until clasp sound is heard Otherwise it may cause electrode conduction failure then the device cannot atomize normally 2 Remove medication cup from...

Страница 5: ...ery life will be affected Remove the batteries if the device won t be used for long time 4 2 Operations for treatment use Preparations before use 1 Remove medication cup please clean and disin fect it...

Страница 6: ...the cup lid and discard residual medication 3 Add 75 ethanol solution in medication cup cover the cup lid then leave for at least 10mins it is advisable to gently shake it for better disinfection 4 Im...

Страница 7: ...medication cup Trickle medication into medication cup re member not to exceed its maximum capacity Improper medication Consult a doctor about whether the medica tion is suitable for the device The ne...

Страница 8: ...ode Keep away from sunlight 55 C 40 C Store between 40 and 55 C Lot number Fragile handle with care Date of manufacture Serial number Follow instructions for use Medical Device complies with Directive...

Страница 9: ...4 2 Air Discharge 2 kV 4 kV 8 kV 15 kV contact 8 kV air Air Discharge 2 kV 4kV 8 kV 15 kV contact 8 kV air Floors should be wood concrete or ce ramic tile If floor is covered with synthetic material...

Страница 10: ...ct was purchased If the equipment is not disposed of correctly fines or penalties may be applied in accordance with the national legislation and regulations GIMA WARRANTY CONDITIONS Congratulations fo...

Отзывы: