7000 Series

Respirator

Full Facepiece

User Instructions for 3M

TM

 Silicone, Small 7800S, Silicone,

Medium 7800S, Silicone, Large 7800S Full Facepieces

Important: Keep these User Instructions for reference.

Summary of Contents for 7000 Series

Page 1: ...1 7000 Series Respirator Full Facepiece User Instructions for 3MTM Silicone Small 7800S Silicone Medium 7800S Silicone Large 7800S Full Facepieces Important Keep these User Instructions for reference ...

Page 2: ...r User Instructions or call 3M These User Instructions provide information about facepiece use only Important information is provided in the User Instructions with each of the air filtration supplied air systems Failure to follow the User Instructions for the air filtration supplied air systems being used may result in sickness or death Do not clean respirator with solvents Cleaning with solvents ...

Page 3: ... substance specific standards In Canada CSA standard Z94 4 requirements must be met 3 The airborne contaminants which can be dangerous to your health include those that are so small you cannot see them 4 Leave contaminated area immediately and contact supervisor if you smell or taste contaminants or if dizziness irritation or other distress occurs 5 Store respirator away from contaminated areas wh...

Page 4: ...pplicable regulations N Never substitute modify add or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to User s Instructions and or maintenance manuals for information on use and maintenance of these respirators P NIOSH does not evaluate respirators for use as surgical masks S Special or critical User s Instructions and or use limitations ...

Page 5: ...tridges retainers or airline accessories Number Description Button Color 7989 7800S S silicone small red 7800S M silicone medium yellow 7800S L silicone large green Number Description 7884 a Lens 7914 b Band Clamp 7916 c Breathing Room Assembly 7999 d Air Inlet Gasket 7890 e Full Face Plug 7283 f Exhalation Valve 7918 g Exhalation Valve Cover 7891 h Cartridge Holder 7893S i Head Strap Assembly Sil...

Page 6: ...Shroud 7925 Spectacle Kit 7930 Fit Test Adapter for quantitative fit testing with 3MTM P100 Filter 7090 7986 Tinted Lens Cover 25 pack 7989 Buttons 7990 Clip on Welding Shield Kit 7991 Electronic Lens Assembly 7993 Welder s Shroud CAUTION Failure to properly dispose of spent cartridges filters or respirators contaminated by hazardous materials can result in environmental harm Handling transportati...

Page 7: ...3MTM 6000 Series Cartridges and 3MTM Filter Retainer 501 Number Description 501 Filter Retainer for 3M Filters 5N11 and 5P71 5N11 N95 Particulate Filter 5P71 P95 Particulate Filter 3MTM 6000 Series Cartridges 701 cartridge filter adapter is required Number Description NIOSH Approved for respiratory protection against the following contaminants up to fifty times the permissible exposure limit with ...

Page 8: ...nations Number Product Name Description 7N11 N95 Particulate Filter Particulate filter N95 use Retainer 7289 when used alone 7090 P100 Particulate Filter Particulate filter P100 use Retainer 7288 when used alone 7251 Organic Vapor Certain organic vapors 7252 Acid Gas Chlorine hydrogen chloride and sulfur dioxide or chlorine dioxide or hydrogen sulfide escape only 7253 Organic Vapor Acid Gas Certai...

Page 9: ...air supplied or combinations of both air supplied and air purifying Separate assembly instructions are required for assembly in powered air purifying systems PAPR and supplied air systems 3M Air Purifying Assembly The facepiece is pre assembled with 3MTM Cartridge Filter Adapters 701 When the cartridge filter adapter 701 is used the bayonet style filters cartridges can be attached directly to the ...

Page 10: ... 3M Adapter Assembly 502 1 Align adapter over cartridge Engage front snap by squeezing front of cartridge and adapter together placing thumbs of both hands over top of adapter and fingers along bottom sides of cartridge Fig 5 2 Engage back snap by squeezing back side of cartridge and adapter together using the same hand positions An audible click should be heard as each snap is engaged Fig 6 The 3...

Page 11: ...et Twist clockwise one quarter turn until it is firmly seated and filter cannot be turned further Repeat for second filter Note The adapter assembly 502 once installed on a 3MTM 6000 Series Cartridge is not to be removed or reused Removal and reuse may result in leakage over exposure sickness or death Fig 7 3M 7000 Series Retainers Filters and Cartridges ...

Page 12: ...idge FR 64 Remove the Cartridge Holders 7891 or Cartridge Filter Adapters 701 from facepiece Before installing the canister cartridge check that the gasket is in place and in good condition Screw the responder canister cartridge into the DIN Port Adapter and tighten with moderate hand pressure In the remaining inlets ensure that gaskets have been properly installed and are not warped or torn Secur...

Page 13: ...apter W 3187 into center opening Fig 9 Fig 9 Fig 10 2 Connect 3MTM Breathing Tube W 3188 to adapter Fig 10 3 Connect 3MTM Breathing Tube W 3188 to air regulator valve Fig 10 4 Check all attachments for secureness See User Instructions included with air regulating valves for further information 3MTM Breathing Tube Assembly W 3264 1 Remove Full Face Plug 7890 and screw in 3MTM Breathing Adapter Tube...

Page 14: ...d Health NIOSH requirement for minimum 4cfm 115 lpm and maximum 15cfm 424 lpm airflow the air control valves approved for use with the 3MTM 7000 Series Respirators must be operated within the supply pressure ranges and hose lengths stated in User Instructions with air regulating valves Failure to do so may result in sickness or death FITTING INSTRUCTIONS Must be followed each time respirator is wo...

Page 15: ...sion of the straps to eliminate leaking and recheck seal If you cannot achieve a proper seal DO NOT enter the contaminated area See your supervisor 3M 2000 Series Filters 1 Place your thumbs onto the center portion of the filters restricting airflow through filters and inhale gently If you feel facepiece collapse slightly and pull closer to your face with no leaks between the face and facepiece a ...

Page 16: ... Fit Test Apparatus FT 10 or FT 30 can be conducted using any of the NIOSH approved 42 CFR 84 Particulate filters Note For further information concerning fit testing contact 3M OH ESD Technical Service at 1 800 243 4630 or a 3M location in your region In Canada call Technical Service at 1 800 267 4414 To conduct QNFT with round retainer type filters the 3MTM Fit Test Adapter 7930 is needed INSPECT...

Page 17: ...mponents before each use to ensure proper operating condition Failure to do so may result in sickness or death 1 Remove cartridges filters and or breathing tubes The center adapter lens and faceseal can also be removed if necessary 2 Clean facepiece excluding filters and cartridges by immersing in warm cleaning solution water temperature not to exceed 120 F 49 C and scrub with soft brush until cle...

Page 18: ... visible from inside the respirator 3MTM Removable DIN Connector 7886 Hold the inside part of the connector secure grasp the outside of the connector and twist counter clockwise to remove To replace the connector press the inner section into the facepiece until the end of the threads are flush with the facepiece exterior then screw on the outer piece by turning clockwise 3MTM Inhalation Valves 728...