Appendix II
Guidance and manufacturer’s declaration – electromagnetic emissions for all EQUIPMENT and SYSTEMS
Guidance and manufacturer’s declaration – electromagnetic immunity – for all EQUIPMENT and SYSTEMS
Guidance and manufacturer’s declaration – electromagnetic immunity – for EQUIPMENT and SYSTEMS that are not
LIFE-SUPPORTING
Guidance and manufacturer’s declaration – electromagnetic emission
The 28066 / NE-M01 is intended for use in the electromagnetic environment specified below. The customer or the user of the
28066 / NE-M01 should make sure that it is used in such an environment.
Emission test
Compliance
Electromagnetic environment – guidance
RF emissions CISPR 11
Group 1
The 28066 / NE-M01 uses RF energy only for its internal function.
Therefore, its RF emissions are very low and are not likely to cause
any interference in nearby electronic equipment.
RF emission CISPR 11
Class B
The 28066 / NE-M01 is suitable for use in all establishments, in-
cluding domestic establishments and those directly connected to
the public low-voltage power supply network that supplies buildings
used for domestic purposes.
Guidance and manufacturer’s declaration – electromagnetic immunity
The 28066 / NE-M01 is intended for use in the electromagnetic environment specified below. The customer or the user of the
28066 / NE-M01 should make sure that it is used in such an environment.
Immunity test
IEC 60601 test level
Compliance level
Electromagnetic environment
guidance
Electrostatic discharge
(ESD) IEC 61000-4-2
Air Discharge: ±2 kV,
±4 kV, ±8 kV, ±15 kV
contact: ±8 kV air
Air Discharge: ±2 kV,
±4kV, ±8 kV, ±15 kV
contact: ±8 kV air
Floors should be wood, concrete or ce-
ramic tile. If floor is covered with synthetic
material, the relative humidity should be
at least 30 %.
Power frequency
(50/60Hz) magnetic
field IEC61000-4-8
30 A/m
30 A/m
Mains power quality should be that of a
typical commercial or hospital environ-
ment.
NOTE:
U
T
is the a.c. mains voltage prior to application of the test level.
Guidance and manufacturer’s declaration – electromagnetic immunity
The 28066 / NE-M01 is intended for use in the electromagnetic environment specified below. The customer or the user of the
28066 / NE-M01 should make sure that it is used in such an environment.
Immunity test
IEC 60601 test level
Compliance
level
Electromagnetic environment
guidance
Radiated RF
IEC 61000-4-3
10 V/m
80 MHz to 2.7 GHz
10 V/m
Portable and mobile RF communications equipment
should be used no closer to any part of the 28066 / NE-
M01, including cables, than the recommended separa-
tion distance calculated from the equation applicable to
the frequency of the transmitter.
Recommended separation distance
80MHz to 800MHz
800MHz to 2,7GHz
Where
P
is the maximum output power rating of the
transmitter in watts (W) according to the transmitter man-
ufacturer and
d
is the recommended separation distance
in metres (m).
Interference may occur in the vi-
cinity of equipment marked with
the following symbol:
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection
from structures, objects and people.
3.5
E
1
√P
d=
7
E
1
√P
d=
3.5
V
1
√P
d=