HS-50 & HS-100
Doc. No 1199-PS-0035 Issue 3
June 2021
___________________________________________________________________________________________
Page 37
StaD - Status Data
Address 00 - Error codes
Bit
Function
0
Transducer pair 1 failed.
1
Transducer pair 2 failed
2
Transducer pair 3 failed
3
Reserved
4
Non-volatile memory error
5
PRT failed
6
Reserved
7
Reserved
Address 01 - Anemometer configuration
Bit
Function
0
Reserved
1
PRT fitted
2
Reserved
3
Reserved
4
0
U, V, W Axis definition (U aligned with transducer axis 1 when viewed
from above)
1
U', V', W' Axis definition (U' aligned with the spar)
5
Reserved
6
Reserved
7
Reserved
Address 02 - Data output configuration 1
Bits 1,0
00
Wind mode UVW
01
Wind mode axis
10
Polar 360 wrap
11
Polar 540 wrap
Bits 3,2
00
±10ms-1 Full Scale Deflection
01
±20ms-1 Full Scale Deflection
10
±30ms-1 Full Scale Deflection
11
±60ms-1 Full Scale Deflection
Bits 5,4
00
SOS report off
01
SOS report speed of sound
10
SOS report sonic temp. K
11
SOS report sonic temp. C
Bits 7,6
00
PRT temp. off
01
PRT temp. K
10
PRT temp. C
11
Reserved
Address 02 is repeated for 8 samples after a power on reset or exit from ‘Interactive Mode’ to allow
the analogue output card or custom PC software to recognise the output configuration.
Address 03 - Data output configuration 2
Bits 2,1,0
000
No inputs enabled
001
1 input enabled
010
2 inputs enabled
011
3 inputs enabled
100
4 inputs enabled
101
5 inputs enabled
110
6 inputs enabled
111
Not used
Bit 3
0
Reserved
1
Reserved
Содержание 1199-PK-085