Page 32
ASCTERM
Syntax:
ASCTERM CR | CRLF
Description:
Sets ASCII output string terminator.
Parameters:
CR
ASCII output string terminator is <CR>.
CRLF
ASCII output string terminator is <CR><LF>.
AVERAGE
Syntax:
AVERAGE 2.to.250 (HS-50) or 1 to 250 (HS-100)
Description:
Sets the number of samples used in the block average. Default is
5
.
Output rate frequency is calculated from 100/Average setting.
e.g. Default Average Setting is 5 therefore Output Rate = 100/5 = 20Hz.
Note:-
If using all 6 analogue inputs then the Average setting must be 50 or more for a Baud rate of
9600, alternatively user a much higher Baud Rate setting.
BAUD
Syntax:
BAUD 2400 | 4800 |
9600
| 19200 | 38400 | 57600 | 115200
Description:
Sets the serial interface baud rate. Selection must be confirmed with a
letter B.
Example of Baud Rate change in a terminal package, assuming HS is in default 9600 Baud:
HS> baud 19200 <CR>
*At this point the Baud Rate of the terminal package must be
changed to that of the new setting for the HS, any delay may
result in an error message.
Confirm> b <CR>
VBAUD
HS> exit
Note:
In general the more parameters required in the output data string and the faster the output
rate the higher must be the Baud rate to get a fully reported data string or change a parameter
setting.
CONFIG
Syntax:
CONFIG
Description:
Reports the anemometer’s configuration.
CTONE
Syntax:
CTONE ON | OFF | DISABLE
Description:
Enables an audible confidence tone
Parameters:
ON
Enables the confidence tone
OFF
Disables the tone until the anemometer is next powered
up.
DISABLE
Disables the tone until the function is enabled
using CTONE ON.
ECHO
Syntax:
ECHO OFF | ON
Description:
Turns on or off character echoing.
Parameters:
OFF
Turn off character echoing.
ON
Turn on character echoing.
EXIT
Syntax:
EXIT
Description:
Exits from interactive mode back to measurement mode.
HELP
Syntax:
HELP
Description:
Reports a brief description of all the available commands.
Syntax:
HELP command
Description:
Reports a description of the command requested.
IM
Syntax:
IM
Description:
Switches from measurement mode to interactive mode.
INCL
Syntax:
INCL
Description
Reports the inclination of the anemometer from the vertical axis.
The format is ±XX.XX, ±YY.YY