14
Model: GBF-35D-VH, GBF-50D-VH
Ventless Hood Operation
2.2.16
Ultra Violet Lamp Installation
1. Install new UV lamp in holding brackets
.
2. Install Lamp Guard and tighten thumb
screws
.
3. Connect UV Lamp wiring harness to
power supply wiring harness
.
4. Install all filters and Access Cover
.
5. Place Fryer power switch in the
ON
position.
4
3
2
1
2.2.17
Hood Filter Alarm Chart
Alarm Sound
What will happen
Filter
Affected
Cause
Solution
Reference
Continuous tone
Alarm will sound and power
to the Fryer heating
elements will shut off.
(If
ILS Model
, power to the
Fryer and the Hood section
will shut off)
Charcoal
Filter dirty
Replace Filter
Sections
2.2.10 &
2.2.11
Continuous tone
Alarm will sound and power
to the Fryer heating
elements will shut off.
(If
ILS Model
, power to the
Fryer and Hood section will
shut off)
Baffle
Filter dirty
Clean Filter
Sections
2.2.2 &
7.2.3
Intermittent tone
Alarm will sound for
two (2) minutes, then
power to the Fryer heating
elements will shut off. (If
ILS Model
, power to the
Fryer and Hood section will
shut off)
E.A.C.
Filter dirty
Clean Filter
Sections
2.2.6,
2.2.7,
2.2.8 &
2.2.9
1
2
4
3