10
Ventless Hood Operation
EAC
EAC
2.2.7
EAC Filter Installation
Filter must align
with this pin
EAC Air Flow
Arrow must point
upward
2.2.8
EAC Filter Status
1
1
2
3
ON
The EAC Filter is in place, powered
and operating normally.
WASH
The EAC Filter has become
excessively dirty and must be
cleaned. If this light is on for more
than 2 minutes, an intermittent alarm
will sound and Fryer heating elements
will be shutdown until the condition is
remedied.
CHECK
The EAC Filter has stopped operating,
it is either not getting a proper
electrical supply or it has been
damaged. If this light is on for more
than 2 minutes an intermittent alarm
will sound and Fryer heating elements
will be shutdown until the condition is
remedied.
The three indicator lights on the Control Panel display the status of the EAC Filter.
2
3
Model: GBF-35D-VH, GBF-50D-VH